Vulnerability identifier: #VU60537
Vulnerability risk: High
CVSSv4.0: 6.1 [CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/U:Amber]
CVE-ID:
CWE-ID:
CWE-787
Exploitation vector: Network
Exploit availability: No
Vulnerable software:
JT2Go
Server applications /
Virtualization software
Teamcenter Visualization
Other software /
Other software solutions
Solid Edge SE2021
Server applications /
SCADA systems
Solid Edge SE2022
Server applications /
SCADA systems
Vendor: Siemens
Description
The vulnerability allows a remote attacker to compromise vulnerable system.
The vulnerability exists due to a boundary error when processing untrusted input in the lmxmlAdapterSE70.dll library. A remote attacker can create a specially crafted PAR file, trick the victim into opening it using the affected software, trigger out-of-bounds write and execute arbitrary code on the target system.
Mitigation
Install updates from vendor's website.
Vulnerable software versions
JT2Go: All versions
Teamcenter Visualization: 12.4 - 13.3
Solid Edge SE2021: before SE2021MP9
Solid Edge SE2022: before SE2022MP1
External links
https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdficsa-22-041-07-1
https://www.zerodayinitiative.com/advisories/ZDI-22-340/
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the Internet.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.