SB2017101803 - Multiple vulnerabilities in Progea Movicon SCADA/HMI



SB2017101803 - Multiple vulnerabilities in Progea Movicon SCADA/HMI

Published: October 18, 2017

Security Bulletin ID SB2017101803
Severity
High
Patch available
NO
Number of vulnerabilities 2
Exploitation vector Remote access
Highest impact Code execution

Breakdown by Severity

High 50% Low 50%
  • Low
  • Medium
  • High
  • Critical

Description

This security bulletin contains information about 2 secuirty vulnerabilities.


1) Insecure DLL loading (CVE-ID: CVE-2017-14017)

The vulnerability allows a remote attacker to compromise vulnerable system.

The vulnerability exists due to insecure .dll loading mechanism when opening files. A remote attacker can place a file along with specially crafted .dll file on a remote SBM or WebDAV share, trick the victim into opening it and execute arbitrary code on the target system with privileges of the current victim.

Successful exploitation of the vulnerability may allow an attacker to compromise vulnerable system.


2) Insecure DLL loading (CVE-ID: CVE-2017-14019)

The vulnerability allows a local attacker to gain elevated privileges on the target system.

The vulnerability exists due to insecure .dll loading mechanism when opening files. A local attacker can place a file along with specially crafted .dll file on a remote SBM or WebDAV share and execute arbitrary code on the target system with elevated privileges.

Successful exploitation of the vulnerability may allow an attacker to compromise vulnerable system.


Remediation

Cybersecurity Help is not aware of any official remediation provided by the vendor.