Risk | Low |
Patch available | YES |
Number of vulnerabilities | 2 |
CVE-ID | CVE-2019-10994 CVE-2019-10980 |
CWE-ID | CWE-125 CWE-843 |
Exploitation vector | Local |
Public exploit | N/A |
Vulnerable software Subscribe |
LAquis SCADA Server applications / SCADA systems |
Vendor | Leão Consultoria e Desenvolvimento de Sistemas |
Security Bulletin
This security bulletin contains information about 2 vulnerabilities.
EUVDB-ID: #VU19945
Risk: Low
CVSSv3.1: 2.2 [CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:U/C:L/I:N/A:N/E:U/RL:O/RC:C]
CVE-ID: CVE-2019-10994
CWE-ID:
CWE-125 - Out-of-bounds read
Exploit availability: No
DescriptionThe vulnerability allows a local attacker to gain access to potentially sensitive information.
The vulnerability exists due to a boundary error when the affected software processes a specially crafted project file. A local attacker can trigger out-of-bounds read error and obtain sensitive information on the system.
MitigationInstall updates from vendor's website.
Vulnerable software versionsLAquis SCADA: 4.3.1.71
External linkshttp://www.us-cert.gov/ics/advisories/icsa-19-213-06
Q & A
Can this vulnerability be exploited remotely?
No. This vulnerability can be exploited locally. The attacker should have authentication credentials and successfully authenticate on the system.
How the attacker can exploit this vulnerability?
The attacker would have to send a specially crafted request to the affected application in order to exploit this vulnerability.
The attacker would have to login to the system and perform certain actions in order to exploit this vulnerability.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.
EUVDB-ID: #VU19944
Risk: Low
CVSSv3.1: 6.8 [CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C]
CVE-ID: CVE-2019-10980
CWE-ID:
CWE-843 - Type confusion
Exploit availability: No
DescriptionThe vulnerability allows a local attacker to execute arbitrary code on the target system.
The vulnerability exists due to a type confusion error when when the affected software processes a specially crafted project file. A local attacker can trigger a type confusion error and execute remote arbitrary code on the target system.
Successful exploitation of this vulnerability may result in complete compromise of vulnerable system.
MitigationInstall updates from vendor's website.
Vulnerable software versionsLAquis SCADA: 4.3.1.71
External linkshttp://www.us-cert.gov/ics/advisories/icsa-19-213-06
Q & A
Can this vulnerability be exploited remotely?
No. This vulnerability can be exploited locally. The attacker should have authentication credentials and successfully authenticate on the system.
How the attacker can exploit this vulnerability?
The attacker would have to send a specially crafted request to the affected application in order to exploit this vulnerability.
The attacker would have to login to the system and perform certain actions in order to exploit this vulnerability.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.