Multiple vulnerabilities in Rockwell Automation EDS Subsystem



Risk Medium
Patch available YES
Number of vulnerabilities 2
CVE-ID CVE-2020-12038
CVE-2020-12034
CWE-ID CWE-119
CWE-89
Exploitation vector Network
Public exploit N/A
Vulnerable software
EDS Subsystem
Other software / Other software solutions

RSLinx Classic
Server applications / SCADA systems

FactoryTalk Linx
Server applications / SCADA systems

RSNetWorx software
Server applications / SCADA systems

Studio 5000 Logix Designer
Client/Desktop applications / Other client software

Vendor Rockwell Automation

Security Bulletin

This security bulletin contains information about 2 vulnerabilities.

1) Buffer overflow

EUVDB-ID: #VU28130

Risk: Medium

CVSSv4.0: 1.7 [CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:A/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:U/U:Green]

CVE-ID: CVE-2020-12038

CWE-ID: CWE-119 - Memory corruption

Exploit availability: No

Description

The vulnerability allows a remote attacker to perform a denial of service (DoS) attack.

The vulnerability exists due to a boundary error in the algorithm that matches square brackets in the EDS subsystem. A remote authenticated attacker can create a specially crafted EDS file, trick the victim into opening it, trigger memory corruption and cause a denial of service condition on the target system.

Mitigation

Install updates from vendor's website.

Vulnerable software versions

EDS Subsystem: - - 28.0.1

RSLinx Classic: - - 4.11.00

FactoryTalk Linx: 6.00 - 6.11

RSNetWorx software: - - 28.00.00

Studio 5000 Logix Designer: - - 32

CPE2.3 External links

https://www.us-cert.gov/ics/advisories/icsa-20-140-01


Q & A

Can this vulnerability be exploited remotely?

Yes. This vulnerability can be exploited by a remote authenticated user via the Internet.

Is there known malware, which exploits this vulnerability?

No. We are not aware of malware exploiting this vulnerability.

2) SQL injection

EUVDB-ID: #VU28131

Risk: Low

CVSSv4.0: 5 [CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:N/E:U/U:Clear]

CVE-ID: CVE-2020-12034

CWE-ID: CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')

Exploit availability: No

Description

The vulnerability allows a remote attacker to execute arbitrary SQL queries in database.

The vulnerability exists due to insufficient sanitization of user-supplied data. A remote attacker on the local network can send a specially crafted EDS file to the affected application and manipulate the database storing the EDS files, leading to denial-of-service conditions.

Mitigation

Install updates from vendor's website.

Vulnerable software versions

EDS Subsystem: - - 28.0.1

RSLinx Classic: - - 4.11.00

FactoryTalk Linx: 6.00 - 6.11

RSNetWorx software: - - 28.00.00

Studio 5000 Logix Designer: - - 32

CPE2.3 External links

https://www.us-cert.gov/ics/advisories/icsa-20-140-01


Q & A

Can this vulnerability be exploited remotely?

Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the local network (LAN).

Is there known malware, which exploits this vulnerability?

No. We are not aware of malware exploiting this vulnerability.



###SIDEBAR###