SB2020102939 - Improper input validation in Oracle Healthcare Data Repository
Published: October 29, 2020
Breakdown by Severity
- Low
- Medium
- High
- Critical
Description
This security bulletin contains information about 1 security vulnerability.
1) Improper input validation (CVE-ID: CVE-2020-2555)
The vulnerability allows a remote non-authenticated attacker to execute arbitrary code.
The vulnerability exists due to improper input validation within the Caching,CacheStore,Invocation component in Oracle Coherence. A remote non-authenticated attacker can exploit this vulnerability to execute arbitrary code.
Remediation
Install update from vendor's website.