Risk | High |
Patch available | YES |
Number of vulnerabilities | 2 |
CVE ID | CVE-2020-28395 CVE-2020-15800 |
CWE ID | CWE-321 CWE-122 |
Exploitation vector | Network |
Public exploit | N/A |
Vulnerable software Subscribe |
SCALANCE X-300 Hardware solutions / Routers & switches, VoIP, GSM, etc |
Vendor | Siemens |
Risk: High
CVSSv3.1: 7.9 [CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N/E:U/RL:O/RC:C] [PCI]
CVE-ID: CVE-2020-28395
CWE-ID:
CWE-321 - Use of Hard-coded Cryptographic Key
Exploit availability: No
DescriptionThe vulnerability allows a remote attacker to compromise the target system.
The vulnerability exists due to affected devices do not create a new unique private key after factory reset. A remote attacker can create a man-in-the-middle situation and decrypt previously captured traffic.
MitigationInstall updates from vendor's website.
Vulnerable software versionsSCALANCE X-300: before 4.1.0
CPE External linkshttps://cert-portal.siemens.com/productcert/pdf/ssa-274900.pdf
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the Internet.
How the attacker can exploit this vulnerability?
The attacker would have to send a specially crafted request to the affected device in order to exploit this vulnerability.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.
Risk: High
CVSSv3.1: 8.5 [CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C] [PCI]
CVE-ID: CVE-2020-15800
CWE-ID:
CWE-122 - Heap-based Buffer Overflow
Exploit availability: No
DescriptionThe vulnerability allows a remote attacker to execute arbitrary code on the target system.
The vulnerability exists due to a boundary error in the web server. A remote attacker can send a specially crafted request, trigger heap-based buffer overflow and execute arbitrary code on the target system.
Successful exploitation of this vulnerability may result in complete compromise of vulnerable system.
MitigationInstall updates from vendor's website.
Vulnerable software versionsSCALANCE X-300: before 4.1.0
CPE External linkshttps://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the Internet.
How the attacker can exploit this vulnerability?
The attacker would have to send a specially crafted request to the affected device in order to exploit this vulnerability.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.