SB2021011306 - Multiple vulnerabilities in Siemens SCALANCE X-300 Switches



SB2021011306 - Multiple vulnerabilities in Siemens SCALANCE X-300 Switches

Published: January 13, 2021

Security Bulletin ID SB2021011306
CSH Severity
High
Patch available
YES
Number of vulnerabilities 2
Exploitation vector Remote access
Highest impact Code execution

Breakdown by Severity

High 100%
  • Low
  • Medium
  • High
  • Critical

Description

This security bulletin contains information about 2 vulnerabilities.


1) Use of Hard-coded Cryptographic Key (CVE-ID: CVE-2020-28395)

CWE-ID: CWE-321 - Use of Hard-coded Cryptographic Key

CVSSv4: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:U/U:Amber


The vulnerability allows a remote attacker to compromise the target system.

The vulnerability exists due to affected devices do not create a new unique private key after factory reset. A remote attacker can create a man-in-the-middle situation and decrypt previously captured traffic.


2) Heap-based buffer overflow (CVE-ID: CVE-2020-15800)

CWE-ID: CWE-122 - Heap-based Buffer Overflow

CVSSv4: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/U:Amber


The vulnerability allows a remote attacker to execute arbitrary code on the target system.

The vulnerability exists due to a boundary error in the web server. A remote attacker can send a specially crafted request, trigger heap-based buffer overflow and execute arbitrary code on the target system.

Successful exploitation of this vulnerability may result in complete compromise of vulnerable system.


Remediation

Install update from vendor's website.