Multiple vulnerabilities in Philips Tasy Electronic Medical Record



Published: 2021-08-27 | Updated: 2021-11-08
Risk High
Patch available YES
Number of vulnerabilities 2
CVE-ID CVE-2021-39375
CVE-2021-39376
CWE-ID CWE-89
Exploitation vector Network
Public exploit N/A
Vulnerable software
Subscribe
Tasy Electronic Medical Record
Server applications / Other server solutions

Vendor Philips

Security Bulletin

This security bulletin contains information about 2 vulnerabilities.

Updated 08.11.2021

Added fixed version for vulnerability #1-2

1) SQL injection

EUVDB-ID: #VU56142

Risk: High

CVSSv3.1: 9 [CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:U/RL:U/RC:C]

CVE-ID: CVE-2021-39375

CWE-ID: CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')

Exploit availability: No

Description

The vulnerability allows a remote attacker to execute arbitrary SQL queries in database.

The vulnerability exists due to insufficient sanitization of user-supplied data in the "FilterValue" parameter in "WAdvancedFilter/getDimensionItemsByCode". A remote attacker can send a specially crafted request to the affected application and execute arbitrary SQL commands within the application database.

Successful exploitation of this vulnerability may allow a remote attacker to read, delete, modify data in database and gain complete control over the affected application.

Mitigation

Install update from vendor's website.

Vulnerable software versions

Tasy Electronic Medical Record: 3.06.1803

External links

http://br.linkedin.com/in/felippe-foppa-6b1434108
http://diesec.home.blog/2021/08/24/philips-tasy-emr-3-06-sql-injection-cve-2021-39375cve-2021-39376/


Q & A

Can this vulnerability be exploited remotely?

Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the Internet.

Is there known malware, which exploits this vulnerability?

No. We are not aware of malware exploiting this vulnerability.

2) SQL injection

EUVDB-ID: #VU56143

Risk: High

CVSSv3.1: 9 [CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:U/RL:U/RC:C]

CVE-ID: CVE-2021-39376

CWE-ID: CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')

Exploit availability: No

Description

The vulnerability allows a remote attacker to execute arbitrary SQL queries in database.

The vulnerability exists due to insufficient sanitization of user-supplied data in the "IE_CORPO_ASSIST" or "CD_USUARIO_CONVENIO" parameters in "CorCad_F2/executaConsultaEspecifico". A remote attacker can send a specially crafted request to the affected application and execute arbitrary SQL commands within the application database.

Successful exploitation of this vulnerability may allow a remote attacker to read, delete, modify data in database and gain complete control over the affected application.

Mitigation

Install update from vendor's website.

Vulnerable software versions

Tasy Electronic Medical Record: 3.06.1803

External links

http://br.linkedin.com/in/felippe-foppa-6b1434108
http://diesec.home.blog/2021/08/24/philips-tasy-emr-3-06-sql-injection-cve-2021-39375cve-2021-39376/