Risk | High |
Patch available | YES |
Number of vulnerabilities | 1 |
CVE-ID | CVE-2022-34465 |
CWE-ID | CWE-119 |
Exploitation vector | Network |
Public exploit | N/A |
Vulnerable software Subscribe |
Simcenter Femap Server applications / SCADA systems Parasolid Client/Desktop applications / Other client software |
Vendor | Siemens |
Security Bulletin
This security bulletin contains one high risk vulnerability.
EUVDB-ID: #VU65260
Risk: High
CVSSv3.1: 7.7 [CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C]
CVE-ID: CVE-2022-34465
CWE-ID:
CWE-119 - Memory corruption
Exploit availability: No
DescriptionThe vulnerability allows a remote attacker to execute arbitrary code on the target system.
The vulnerability exists due to a boundary error while parsing specially crafted NEU files. A remote attacker can create a specially crafted NEU file, trick the victim into opening it, trigger memory corruption and execute arbitrary code on the target system.
Successful exploitation of this vulnerability may result in complete compromise of vulnerable system.
MitigationInstall updates from vendor's website.
Vulnerable software versionsSimcenter Femap: All versions
Parasolid: 33.1 - 34.1
External linkshttp://cert-portal.siemens.com/productcert/pdf/ssa-243317.pdf
http://www.zerodayinitiative.com/advisories/ZDI-22-965/icsa-22-195-09
Q & A
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the Internet.
How the attacker can exploit this vulnerability?
The attacker would have to send a specially crafted request to the affected application in order to exploit this vulnerability.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.