Risk | High |
Patch available | YES |
Number of vulnerabilities | 3 |
CVE-ID | CVE-2022-28807 CVE-2022-28808 CVE-2022-28809 |
CWE-ID | CWE-119 |
Exploitation vector | Network |
Public exploit | N/A |
Vulnerable software Subscribe |
Teamcenter Visualization Other software / Other software solutions JT2Go Server applications / Virtualization software |
Vendor | Siemens |
Security Bulletin
This security bulletin contains information about 3 vulnerabilities.
EUVDB-ID: #VU65289
Risk: High
CVSSv3.1: 7.7 [CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C]
CVE-ID: CVE-2022-28807
CWE-ID:
CWE-119 - Memory corruption
Exploit availability: No
DescriptionThe vulnerability allows a remote attacker to execute arbitrary code on the target system.
The vulnerability exists due to a boundary error. A remote attacker can create a specially crafted DWG file, trick the victim into opening it, trigger memory corruption and execute arbitrary code on the target system.
Successful exploitation of this vulnerability may result in complete compromise of vulnerable system.
MitigationInstall updates from vendor's website.
Vulnerable software versionsTeamcenter Visualization: 12.4 - 14.0
JT2Go: before 13.3.0.5
External linkshttp://cert-portal.siemens.com/productcert/txt/ssa-429204.txticsa-22-195-11
Q & A
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the Internet.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.
EUVDB-ID: #VU65290
Risk: High
CVSSv3.1: 7.7 [CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C]
CVE-ID: CVE-2022-28808
CWE-ID:
CWE-119 - Memory corruption
Exploit availability: No
DescriptionThe vulnerability allows a remote attacker to execute arbitrary code on the target system.
The vulnerability exists due to a boundary error. A remote attacker can create a specially crafted DWG file, trick the victim into opening it, trigger memory corruption and execute arbitrary code on the target system.
Successful exploitation of this vulnerability may result in complete compromise of vulnerable system.
MitigationInstall updates from vendor's website.
Vulnerable software versionsTeamcenter Visualization: 12.4 - 14.0
JT2Go: before 13.3.0.5
External linkshttp://cert-portal.siemens.com/productcert/txt/ssa-429204.txt
http://fortiguard.com/zeroday/FG-VD-22-002icsa-22-195-11
Q & A
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the Internet.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.
EUVDB-ID: #VU65291
Risk: High
CVSSv3.1: 7.7 [CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C]
CVE-ID: CVE-2022-28809
CWE-ID:
CWE-119 - Memory corruption
Exploit availability: No
DescriptionThe vulnerability allows a remote attacker to execute arbitrary code on the target system.
The vulnerability exists due to a boundary error. A remote attacker can create a specially crafted DWG file, trick the victim into opening it, trigger memory corruption and execute arbitrary code on the target system.
Successful exploitation of this vulnerability may result in complete compromise of vulnerable system.
MitigationInstall updates from vendor's website.
Vulnerable software versionsTeamcenter Visualization: 12.4 - 14.0
JT2Go: before 13.3.0.5
External linkshttp://cert-portal.siemens.com/productcert/txt/ssa-429204.txt
http://fortiguard.com/zeroday/FG-VD-22-004icsa-22-195-11
Q & A
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the Internet.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.