SB2023041709 - Path traversal in Triangle MicroWorks SCADA Data Gateway



SB2023041709 - Path traversal in Triangle MicroWorks SCADA Data Gateway

Published: April 17, 2023

Security Bulletin ID SB2023041709
CSH Severity
Low
Patch available
NO
Number of vulnerabilities 1
Exploitation vector Remote access
Highest impact Code execution

Breakdown by Severity

Low 100%
  • Low
  • Medium
  • High
  • Critical

Description

This security bulletin contains information about 1 vulnerability.


1) Path traversal (CVE-ID: CVE-2022-0369)

CWE-ID: CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')

CVSSv4: CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/U:Clear


The vulnerability allows a remote user to perform directory traversal attacks.

The vulnerability exists due to input validation error when processing directory traversal sequences within the Restore Workspace feature. A remote administrator can send a specially crafted HTTP request and read arbitrary files on the system, leading to arbitrary code execution.


Remediation

Cybersecurity Help is not aware of any official remediation provided by the vendor.