SB2023113037 - IBM Maximo Application Suite - Monitor Component update for Systeminformation
Published: November 30, 2023
Breakdown by Severity
- Low
- Medium
- High
- Critical
Description
This security bulletin contains information about 1 vulnerability.
1) Command Injection (CVE-ID: CVE-2023-42810)
CWE-ID: CWE-77 - Command injection
CVSSv4: CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/U:Green
The vulnerability allows a remote attacker to execute arbitrary commands on the system.
The vulnerability exists due to improper input validation within the wifiConnections() and wifiNetworks() functions when processing data passed via the SSID. A remote attacker can send specially crafted SSID identifier to the application and execute arbitrary OS commands on the system.
Remediation
Install update from vendor's website.