Risk | Low |
Patch available | YES |
Number of vulnerabilities | 1 |
CVE-ID | CVE-2023-32737 |
CWE-ID | CWE-502 |
Exploitation vector | Local |
Public exploit | N/A |
Vulnerable software Subscribe |
Totally Integrated Automation Portal (TIA Portal) Other software / Other software solutions SIMATIC STEP 7 Safety Server applications / SCADA systems |
Vendor |
Security Bulletin
This security bulletin contains one low risk vulnerability.
EUVDB-ID: #VU94200
Risk: Low
CVSSv3.1: 5.5 [CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C]
CVE-ID: CVE-2023-32737
CWE-ID:
CWE-502 - Deserialization of Untrusted Data
Exploit availability: No
DescriptionThe vulnerability allows a local user to execute arbitrary code on the target system.
The vulnerability exists due to insecure input validation when processing serialized data within the .NET BinaryFormatter. A local administrator can pass specially crafted data to the application and execute arbitrary code on the target system.
Successful exploitation of this vulnerability may result in complete compromise of vulnerable system.
MitigationInstall updates from vendor's website.
Vulnerable software versionsTotally Integrated Automation Portal (TIA Portal): before 18 Update 2
SIMATIC STEP 7 Safety: before 18 Update 2
External linkshttp://cert-portal.siemens.com/productcert/html/ssa-313039.html
Q & A
Can this vulnerability be exploited remotely?
No. This vulnerability can be exploited locally. The attacker should have authentication credentials and successfully authenticate on the system.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.