Risk | Low |
Patch available | YES |
Number of vulnerabilities | 1 |
CVE-ID | CVE-2024-43781 |
CWE-ID | CWE-532 |
Exploitation vector | Local |
Public exploit | N/A |
Vulnerable software |
SINUMERIK 828D Server applications / SCADA systems SINUMERIK 840D sl Server applications / SCADA systems SINUMERIK ONE Hardware solutions / Firmware |
Vendor | Siemens |
Security Bulletin
This security bulletin contains one low risk vulnerability.
EUVDB-ID: #VU97162
Risk: Low
CVSSv3.1: 4.8 [CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:U/RL:O/RC:C]
CVE-ID: CVE-2024-43781
CWE-ID:
CWE-532 - Information Exposure Through Log Files
Exploit availability: No
DescriptionThe vulnerability allows a local user to gain access to sensitive information.
The vulnerability exists due to software stores sensitive information into log files within the Create MyConfig (CMC). A local user can read the log files and gain access to sensitive data.
MitigationInstall updates from vendor's website.
Vulnerable software versionsSINUMERIK 828D: 4
SINUMERIK 840D sl: 4
SINUMERIK ONE: before 6.15 SP4
CPE2.3http://cert-portal.siemens.com/productcert/html/ssa-097786.html
http://www.cisa.gov/news-events/ics-advisories/icsa-24-256-04
Q & A
Can this vulnerability be exploited remotely?
No. This vulnerability can be exploited locally. The attacker should have authentication credentials and successfully authenticate on the system.
How the attacker can exploit this vulnerability?
The attacker would have to send a specially crafted request to the affected application in order to exploit this vulnerability.
The attacker would have to login to the system and perform certain actions in order to exploit this vulnerability.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.