SB2025081240 - Multiple vulnerabilities in Ivanti Connect Secure and Policy Secure
Published: August 12, 2025
Breakdown by Severity
- Low
- Medium
- High
- Critical
Description
This security bulletin contains information about 4 vulnerabilities.
1) Out-of-bounds read (CVE-ID: CVE-2025-5456)
CWE-ID: CWE-125 - Out-of-bounds read
CVSSv4: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:U/U:Green
The vulnerability allows a remote attacker to perform a denial of service (DoS) attack.
The vulnerability exists due to a boundary condition. A remote attacker can send specially crafted requests to the system, trigger an out-of-bounds read error and perform a denial of service (DoS) attack.
2) NULL pointer dereference (CVE-ID: CVE-2025-5462)
CWE-ID: CWE-476 - NULL Pointer Dereference
CVSSv4: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:U/U:Green
The vulnerability allows a remote attacker to perform a denial of service (DoS) attack.
The vulnerability exists due to a NULL pointer dereference error. A remote attacker can send specially crafted packets to the system and perform a denial of service (DoS) attack.
3) XML Entity Expansion (CVE-ID: CVE-2025-5466)
CWE-ID: CWE-776 - Improper Restriction of Recursive Entity References in DTDs ('XML Entity Expansion')
CVSSv4: CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:U/U:Clear
The vulnerability allows a remote user to perform a denial of service attack.
The vulnerability exists due to insufficient input validation when handling XML data. A remote user with admin privileged can perform a denial of service (DoS) attack.
4) Link following (CVE-ID: CVE-2025-5468)
CWE-ID: CWE-59 - Improper Link Resolution Before File Access ('Link Following')
CVSSv4: CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:U/U:Clear
The vulnerability allows a local user to read arbitrary files on the system.
The vulnerability exists due to an insecure link following issue. A local user can create a specially crafted symbolic link to a critical file on the system and read its contents.
Remediation
Install update from vendor's website.