SB20250908107 - Multiple vulnerabilities in Schneider Electric EcoStruxure Power Monitoring Expert and EcoStruxure Power Operation Advanced Reporting and Dashboards Module
Published: September 8, 2025
Breakdown by Severity
- Low
- Medium
- High
- Critical
Description
This security bulletin contains information about 4 vulnerabilities.
1) Path traversal (CVE-ID: CVE-2025-54926)
CWE-ID: CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVSSv4: CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/U:Clear
The vulnerability allows a remote user to perform directory traversal attacks.
The vulnerability exists due to input validation error when processing directory traversal sequences. A remote administrator can send a specially crafted HTTP request and upload arbitrary files on the system, leading to arbitrary code execution.
2) Path traversal (CVE-ID: CVE-2025-54927)
CWE-ID: CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVSSv4: CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:U/U:Clear
The vulnerability allows a remote user to perform directory traversal attacks.
The vulnerability exists due to input validation error when processing directory traversal sequences. A remote administrator can send a specially crafted HTTP request and read arbitrary files on the system.
3) Server-Side Request Forgery (SSRF) (CVE-ID: CVE-2025-54924)
CWE-ID: CWE-918 - Server-Side Request Forgery (SSRF)
CVSSv4: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:U/U:Green
The disclosed vulnerability allows a remote attacker to perform SSRF attacks.
The vulnerability exists due to insufficient validation of user-supplied input. A remote attacker can send a specially crafted HTTP request and trick the application to initiate requests to arbitrary systems.
Successful exploitation of this vulnerability may allow a remote attacker gain access to sensitive data, located in the local network or send malicious requests to other servers from the vulnerable system.
4) Server-Side Request Forgery (SSRF) (CVE-ID: CVE-2025-54925)
CWE-ID: CWE-918 - Server-Side Request Forgery (SSRF)
CVSSv4: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:U/U:Green
The disclosed vulnerability allows a remote attacker to perform SSRF attacks.
The vulnerability exists due to insufficient validation of user-supplied input. A remote attacker can send a specially crafted HTTP request and trick the application to initiate requests to arbitrary systems.
Successful exploitation of this vulnerability may allow a remote attacker gain access to sensitive data, located in the local network or send malicious requests to other servers from the vulnerable system.
Remediation
Install update from vendor's website.