SB2025112102 - Multiple vulnerabilities in LogStare Collector



SB2025112102 - Multiple vulnerabilities in LogStare Collector

Published: November 21, 2025

Security Bulletin ID SB2025112102
Severity
High
Patch available
YES
Number of vulnerabilities 6
Exploitation vector Remote access
Highest impact Code execution

Breakdown by Severity

High 17% Medium 17% Low 67%
  • Low
  • Medium
  • High
  • Critical

Description

This security bulletin contains information about 6 secuirty vulnerabilities.


1) Incorrect default permissions (CVE-ID: CVE-2025-58097)

The vulnerability allows a local user to execute arbitrary code on the system.

The vulnerability exists due to incorrect default permissions for files and folders that are set by the application. A local user can manipulate files within the installation directory of the product and execute arbitrary code on the target system.


2) Cross-site scripting (CVE-ID: CVE-2025-61949)

The disclosed vulnerability allows a remote attacker to perform cross-site scripting (XSS) attacks.

The vulnerability exists due to insufficient sanitization of user-supplied data in UserManagement. A remote user can inject and execute arbitrary HTML and script code in user's browser in context of vulnerable website.

Successful exploitation of this vulnerability may allow a remote attacker to steal potentially sensitive information, change appearance of the web page, perform phishing and drive-by-download attacks.


3) Incorrect authorization (CVE-ID: CVE-2025-62189)

The vulnerability allows a remote attacker to bypass authorization checks.

The vulnerability exists due to incorrect authorization in UserRegistration. A remote user can send a specially crafted HTTP request and create a new user account.


4) Cross-site request forgery (CVE-ID: CVE-2025-62687)

The vulnerability allows a remote attacker to perform cross-site request forgery attacks.

The vulnerability exists due to insufficient validation of the HTTP request origin. A remote attacker can trick the victim to visit a specially crafted web page and perform arbitrary actions on behalf of the victim on the vulnerable website.


5) Insertion of Sensitive Information Into Sent Data (CVE-ID: CVE-2025-64299)

The vulnerability allows a remote user to gain access to potentially sensitive information.

The vulnerability exists due to insertion of sensitive information into sent data. A remote administrator can obtain the other users' password hashes.


6) Insecure DLL loading (CVE-ID: CVE-2025-64695)

The vulnerability allows a remote attacker to compromise vulnerable system.

The vulnerability exists due to the application loads DLL libraries in an insecure manner. A remote attacker can place a specially crafted .dll file, trick the victim into opening a file and execute arbitrary code on victim's system.


Remediation

Install update from vendor's website.