SB2026082534 - Multiple vulnerabilities in FURUNO ELECTRIC FA-50



SB2026082534 - Multiple vulnerabilities in FURUNO ELECTRIC FA-50

Published: August 25, 2026

Security Bulletin ID SB2026082534
CSH Severity
High
Patch available
NO
Number of vulnerabilities 2
Exploitation vector Remote access
Highest impact Data manipulation

Breakdown by Severity

High 50% Medium 50%
  • Low
  • Medium
  • High
  • Critical

Description

This security bulletin contains information about 2 vulnerabilities.


1) Use of hard-coded credentials (CVE-ID: CVE-2026-59769)

CWE-ID: CWE-798 - Use of Hard-coded Credentials

CVSSv4: 8.8 [CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N]


The vulnerability allows a remote attacker to gain full access to vulnerable system.

The vulnerability exists due to presence of hard-coded credentials in application code. A remote unauthenticated attacker can operate the settings screen to alter the settings of the device.


2) Missing Authentication for Critical Function (CVE-ID: CVE-2026-67578)

CWE-ID: CWE-306 - Missing Authentication for Critical Function

CVSSv4: 8.7 [CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N]


The vulnerability allows a remote attacker to bypass authentication process.

The vulnerability exists due to missing authentication for critical function. A remote attacker can change configuration on the management screen without authentication.


Remediation

Cybersecurity Help is not aware of any official remediation provided by the vendor.