SB20260912226 - Always-Incorrect Control Flow Implementation in Linux kernel md driver
Published: September 12, 2026
Breakdown by Severity
- Low
- Medium
- High
- Critical
Description
This security bulletin contains information about 1 vulnerability.
1) Always-Incorrect Control Flow Implementation (CVE-ID: CVE-2026-89558)
CWE-ID: CWE-670 - Always-Incorrect Control Flow Implementation
CVSSv4: 6.7 [CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N]
The vulnerability allows a local privileged user to cause silent data corruption.
The vulnerability exists due to incorrect control flow implementation in raid10_sync_request() in drivers/md/raid10.c when recovering RAID10 devices while another mirror remains missing. A local privileged user can write to a degraded RAID10 array and re-add affected devices to cause silent data corruption.
Exploitation requires bitmap-based recovery.
Remediation
Install update from vendor's website.