SB20261125151 - Multiple vulnerabilities in systemd
Published: November 25, 2026
Breakdown by Severity
- Low
- Medium
- High
- Critical
Description
This security bulletin contains information about 6 vulnerabilities.
1) Reachable assertion (CVE-ID: N/A)
CWE-ID: CWE-617 - Reachable Assertion
CVSSv4: 6.9 [CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N]
The vulnerability allows a remote attacker to cause a denial of service by freezing systemd as PID 1.
The vulnerability exists due to a reachable assertion in the systemd UserDatabase Varlink handler when it processes malformed user lookup parameters. A remote attacker can submit a malformed user lookup request over local IPC to trigger the assertion and halt processing in PID 1.
2) Path traversal (CVE-ID: CVE-2026-15059)
CWE-ID: CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVSSv4: 6.8 [CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N]
The vulnerability allows a local user to cause a denial of service by terminating arbitrary local processes, including privileged processes that systemd-oomd can signal.
The vulnerability exists due to path traversal in the systemd-oomd managed OOM reporting interface when it checks ownership before resolving the supplied cgroup path and fails to verify that the resolved path remains within the cgroup filesystem. A local user can submit a crafted managed OOM report to make the daemon use attacker-controlled cgroup data and terminate selected processes.
3) Allocation of Resources Without Limits or Throttling (CVE-ID: N/A)
CWE-ID: CWE-770 - Allocation of Resources Without Limits or Throttling
CVSSv4: 4.8 [CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N]
The vulnerability allows a local user to cause a denial of service by making affected systemd processes crash or become unresponsive.
The vulnerability exists due to insufficient resource limits in systemd's D-Bus and Varlink interfaces when processing local requests. A local user can submit resource-intensive requests through either interface to disrupt affected systemd services.
4) Improper privilege management (CVE-ID: N/A)
CWE-ID: CWE-269 - Improper Privilege Management
CVSSv4: 2.1 [CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N]
The vulnerability allows a remote attacker to read KEY=value lines from local text files protected by discretionary access controls.
The vulnerability exists due to improper privilege management in systemd-machined when it reads OS release metadata with host root privileges inside a caller-controlled mount namespace. A remote attacker can use an active local graphical session to request machine metadata through D-Bus or Varlink and retrieve protected key-value pairs.
5) Allocation of Resources Without Limits or Throttling (CVE-ID: N/A)
CWE-ID: CWE-770 - Allocation of Resources Without Limits or Throttling
CVSSv4: 4.8 [CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N]
The vulnerability allows a local user to cause a denial of service by exhausting memory and potentially crashing systemd services.
The vulnerability exists due to unbounded parser stack growth in libsystemd's sd-json module when processing nested JSON arrays or objects before the output depth check runs. A local user can send a crafted JSON message to an accessible Varlink service to trigger excessive heap allocation during parsing.
6) Improper Neutralization of Special Elements in Output Used by a Downstream Component (CVE-ID: N/A)
CWE-ID: CWE-74 - Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVSSv4: 5.4 [CVSS:4.0/AV:P/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N]
The vulnerability allows an attacker with physical access to system to start a systemd unit of their choice, potentially gaining a root console.
The vulnerability exists due to improper neutralization of newline characters in udev's scsi_id helper when it exports SCSI world wide name fields as device properties. An attacker with physical access to system can present a malicious SCSI device through USB mass storage, iSCSI, or a virtual SCSI adapter to inject a device property that triggers privileged unit activation.
Remediation
Install update from vendor's website.
References
- https://github.com/systemd/systemd/security/advisories/GHSA-848h-497j-8vjq
- https://github.com/systemd/systemd/security/advisories/GHSA-652q-wxr6-h5j6
- https://github.com/systemd/systemd/commit/cde88c4ea364e816619f385a870d074ebc12fe0f
- https://github.com/systemd/systemd/security/advisories/GHSA-3jgj-3phh-hx5j
- https://github.com/systemd/systemd/security/advisories/GHSA-2p9f-rcmv-x36h
- https://github.com/systemd/systemd/security/advisories/GHSA-5rm9-cc37-35gq
- https://github.com/systemd/systemd/security/advisories/GHSA-m8q3-73v4-wvg7