Improper access control in OpenEMR - CVE-2026-104136

 

Improper access control in OpenEMR - CVE-2026-104136

Published: August 18, 2026 / Updated: November 6, 2026


Vulnerability identifier: #VU144021
CSH Severity: Low
CVSS v4: 7.1 [CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N]
CVE-ID: CVE-2026-104136
CWE-ID: CWE-284
Exploitation vector: Remote access
Exploit availability: No public exploit available

Vulnerability details

The vulnerability allows a remote user to disclose sensitive patient information.

The vulnerability exists due to improper access control in the /interface/main/messages/save.php action=new_recall branch when handling crafted POST requests with a supplied patient pid. A remote user can send a crafted request with an arbitrary patient ID to disclose sensitive patient information.

The exposed data can include recall information, contact fields, HIPAA notification preferences, patient details, and recent appointment information.


Affected software

OpenEMR

How to mitigate CVE-2026-104136

Install security update from vendor's website.

OpenEMR - update to 8.3.0

External References

Related Security Bulletins