Integer overflow in Siemens products - CVE-2018-11458

 

Integer overflow in Siemens products - CVE-2018-11458

Published: December 12, 2018


Vulnerability identifier: #VU16505
CSH Severity: High
CVSS v4.0: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/U:Amber
CVE-ID: CVE-2018-11458
CWE-ID: CWE-190
Exploitation vector: Remote access
Exploit availability: No public exploit available
Vendor: Siemens
Affected software:
SINUMERIK 808D
SINUMERIK 840D
SINUMERIK 828D

Detailed vulnerability description

The vulnerability allows a remote attacker to execute arbitrary code on the target system.

The vulnerability exists due to integer overflow when handling malicious input if Port 4842/TCP is manually opened in the firewall configuration of network Port X130. A remote unauthenticated attacker can specially crafted network requests to Port 4842/TCP, trigger memory corruption and execute arbitrary code with privileged permissions.

Successful exploitation of this vulnerability may result in complete compromise of vulnerable system.


How to mitigate CVE-2018-11458

Update SINUMERIK 828D to version 4.7 SP6 HF1.
Update SINUMERIK 840D to version 4.7 SP6 HF5 or 4.8 SP3.