Cross-site scripting in Cisco SPA112 2-Port Phone Adapter - CVE-2019-1956

 

Cross-site scripting in Cisco SPA112 2-Port Phone Adapter - CVE-2019-1956

Published: August 20, 2019


Vulnerability identifier: #VU20324
CSH Severity: Low
CVSS v4: 4.8 [CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N]
CVE-ID: CVE-2019-1956
CWE-ID: CWE-79
Exploitation vector: Remote access
Exploit availability: No public exploit available

Vulnerability details

The disclosed vulnerability allows a remote attacker to perform cross-site scripting (XSS) attacks against another user of the device.

The vulnerability exists due to insufficient sanitization of user-supplied data in the web-based interface of the affected device. A remote authenticated attacker can insert malicious code in one of the configuration fields and execute arbitrary HTML and script code in user's browser in context of vulnerable website.

Successful exploitation of this vulnerability may allow a remote attacker to steal potentially sensitive information, change appearance of the web page, perform phishing and drive-by-download attacks.


Affected software

Cisco SPA112 2-Port Phone Adapter

How to mitigate CVE-2019-1956

Install updates from vendor's website.

Cisco SPA112 2-Port Phone Adapter - update to 1.4.1SR4

External References

Related Security Bulletins