Heap-based buffer overflow in freeswitch - CVE-2015-7392

 

Heap-based buffer overflow in freeswitch - CVE-2015-7392

Published: October 5, 2015 / Updated: December 27, 2023


Vulnerability identifier: #VU40644
CSH Severity: High
CVSSv4.0: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/U:Amber
CVE-ID: CVE-2015-7392
CWE-ID: CWE-122
Exploitation vector: Remote access
Exploit availability: No public exploit available
Vulnerable software:
freeswitch
Software vendor:
www.freeswitch.org

Description

The vulnerability allows a remote attacker to execute arbitrary code on the target system.

The vulnerability exists due to a boundary error in the parse_string() function in libs/esl/src/esl_json.c. A remote attacker can pass specially crafted data to the application to trigger a heap-based buffer overflow and execute arbitrary code on the target system.

Successful exploitation of this vulnerability may result in complete compromise of vulnerable system.


Remediation

Install update from vendor's website.

External links