Out-of-bounds write in Siemens products - CVE-2021-44018

 

Out-of-bounds write in Siemens products - CVE-2021-44018

Published: February 11, 2022 / Updated: February 16, 2022


Vulnerability identifier: #VU60537
CSH Severity: High
CVSS v4: 8.6 [CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N]
CVE-ID: CVE-2021-44018
CWE-ID: CWE-787
Exploitation vector: Remote access
Exploit availability: No public exploit available

Vulnerability details

The vulnerability allows a remote attacker to compromise vulnerable system.

The vulnerability exists due to a boundary error when processing untrusted input in the lmxmlAdapterSE70.dll library. A remote attacker can create a specially crafted PAR file, trick the victim into opening it using the affected software, trigger out-of-bounds write and execute arbitrary code on the target system.


Affected software

JT2Go
Teamcenter Visualization
Solid Edge SE2021
Solid Edge SE2022

How to mitigate CVE-2021-44018

Install updates from vendor's website.

Teamcenter Visualization - update to 13.3.0.1
Solid Edge SE2021 - update to SE2021MP9
Solid Edge SE2022 - update to SE2022MP1

External References

Related Security Bulletins