#VU65293 Use of insufficiently random values in Siemens products - CVE-2022-26647
Published: July 14, 2022 / Updated: July 14, 2022
Vulnerability identifier: #VU65293
Vulnerability risk: High
CVSSv4.0: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/U:Amber
CVE-ID: CVE-2022-26647
CWE-ID: CWE-330
Exploitation vector: Remote access
Exploit availability:
No public exploit available
Vulnerable software:
SCALANCE X200-4P IRT
SCALANCE X201-3P IRT
SCALANCE X201-3P IRT PRO
SCALANCE X202-2IRT
SCALANCE X202-2P IRT
SCALANCE X202-2P IRT PRO
SCALANCE X204IRT
SCALANCE X204IRT PRO
SCALANCE XF201-3P IRT
SCALANCE XF202-2P IRT
SCALANCE XF204-2BA IRT
SCALANCE XF204IRT
SCALANCE X204-2
SCALANCE X204-2FM
SCALANCE X204-2LD
SCALANCE X204-2LD TS
SCALANCE X204-2TS
SCALANCE X206-1
SCALANCE X206-1LD
SCALANCE X208
SCALANCE X208PRO
SCALANCE X212-2
SCALANCE X212-2LD
SCALANCE X216
SCALANCE X224
SCALANCE XF204
SCALANCE XF204-2
SCALANCE XF206-1
SCALANCE XF208
SCALANCE X200-4P IRT
SCALANCE X201-3P IRT
SCALANCE X201-3P IRT PRO
SCALANCE X202-2IRT
SCALANCE X202-2P IRT
SCALANCE X202-2P IRT PRO
SCALANCE X204IRT
SCALANCE X204IRT PRO
SCALANCE XF201-3P IRT
SCALANCE XF202-2P IRT
SCALANCE XF204-2BA IRT
SCALANCE XF204IRT
SCALANCE X204-2
SCALANCE X204-2FM
SCALANCE X204-2LD
SCALANCE X204-2LD TS
SCALANCE X204-2TS
SCALANCE X206-1
SCALANCE X206-1LD
SCALANCE X208
SCALANCE X208PRO
SCALANCE X212-2
SCALANCE X212-2LD
SCALANCE X216
SCALANCE X224
SCALANCE XF204
SCALANCE XF204-2
SCALANCE XF206-1
SCALANCE XF208
Software vendor:
Siemens
Siemens
Description
The vulnerability allows a remote attacker to compromise the target system.
The vulnerability exists due to the webserver of affected devices calculates session ids and nonces in an insecure manner. A remote attacker can brute-force session ids and hijack existing sessions.
Remediation
Install updates from vendor's website.