Use of insufficiently random values in Siemens products - CVE-2022-46353

 

Use of insufficiently random values in Siemens products - CVE-2022-46353

Published: December 16, 2022


Vulnerability identifier: #VU70392
CSH Severity: High
CVSS v4: 8.6 [CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N]
CVE-ID: CVE-2022-46353
CWE-ID: CWE-330
Exploitation vector: Remote access
Exploit availability: No public exploit available

Vulnerability details

The vulnerability allows a remote attacker to compromise the target system.

The vulnerability exists due to the webserver of affected devices calculates session ids and nonces in an insecure manner. A remote attacker can brute-force session ids and hijack existing sessions.


Affected software

SCALANCE X204RNA (HSR)
SCALANCE X204RNA (PRP)
SCALANCE X204RNA EEC (HSR)
SCALANCE X204RNA EEC (PRP)
SCALANCE X204RNA EEC (PRP/HSR)

How to mitigate CVE-2022-46353

Install updates from vendor's website.

SCALANCE X204RNA (HSR) - update to 3.2.7
SCALANCE X204RNA (PRP) - update to 3.2.7
SCALANCE X204RNA EEC (HSR) - update to 3.2.7
SCALANCE X204RNA EEC (PRP) - update to 3.2.7
SCALANCE X204RNA EEC (PRP/HSR) - update to 3.2.7

External References

Related Security Bulletins