Improper access control in Siemens products - CVE-2023-23835

 

Improper access control in Siemens products - CVE-2023-23835

Published: February 21, 2023 / Updated: February 22, 2023


Vulnerability identifier: #VU72460
CSH Severity: Medium
CVSS v4: 8.2 [CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N]
CVE-ID: CVE-2023-23835
CWE-ID: CWE-284
Exploitation vector: Remote access
Exploit availability: No public exploit available

Vulnerability details

The vulnerability allows a remote attacker to gain unauthorized access to otherwise restricted functionality.

The vulnerability exists due to improper access restrictions. A remote attacker can bypass XPath constraints and retrieve information using XPath queries that trigger errors.


Affected software

Mendix Applications using Mendix 7
Mendix Applications using Mendix 8
Mendix Applications using Mendix 9

How to mitigate CVE-2023-23835

Install updates from vendor's website.

Mendix Applications using Mendix 7 - update to 7.23.34
Mendix Applications using Mendix 8 - update to 8.18.23
Mendix Applications using Mendix 9 - addressed in versions 9.6.15, 9.12.10, 9.18.4, 9.22.0