Incorrect default permissions in National Instruments products - CVE-2024-1155

 

Incorrect default permissions in National Instruments products - CVE-2024-1155

Published: March 1, 2024


Vulnerability identifier: #VU86933
CSH Severity: Low
CVSS v4: 8.5 [CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N]
CVE-ID: CVE-2024-1155
CWE-ID: CWE-276
Exploitation vector: Local access
Exploit availability: No public exploit available

Vulnerability details

The vulnerability allows a local user to escalate privileges on the system.

The vulnerability exists due to incorrect default permissions within the userservices executable and TagHistorian, DocumentManager, SkylineService, ServiceRegistry components. A local user with access to the system can view contents of files and directories or modify them.


Affected software

FlexLogger
SystemLink Server
Specification Compliance Manager
G Web Development Software
Static Test Software Suite
Data Record AD
STS Software Bundle
LabVIEW NXG Web Module
LabVIEW NXG Real-Time Module
LabVIEW NXG Community Edition

How to mitigate CVE-2024-1155

Install updates from vendor's website.

SystemLink Server - update to 2024 Q1