Vulnerability identifier: #VU103599
Vulnerability risk: Low
CVSSv4.0: 1.1 [CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:A/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N/E:U/U:Clear]
CVE-ID:
CWE-ID:
CWE-79
Exploitation vector: Network
Exploit availability: No
Vulnerable software:
EcoStruxure Power Monitoring Expert
Server applications /
SCADA systems
EcoStruxure Power Operation
Server applications /
SCADA systems
EcoStruxure Power Operation with Advanced Reports
Server applications /
SCADA systems
EcoStruxure Power SCADA Operation with Advanced Reports
Server applications /
SCADA systems
Vendor: Schneider Electric
Description
The disclosed vulnerability allows a remote attacker to perform cross-site scripting (XSS) attacks.
The vulnerability exists due to insufficient sanitization of user-supplied data. A remote user can trick the victim to follow a specially crafted link and execute arbitrary HTML and script code in user's browser in context of vulnerable website.
Successful exploitation of this vulnerability may allow a remote attacker to steal potentially sensitive information, change appearance of the web page, perform phishing and drive-by-download attacks.
Mitigation
Install updates from vendor's website.
Vulnerable software versions
EcoStruxure Power Monitoring Expert: 2020 - 2021
EcoStruxure Power Operation: 2021 - 2022
EcoStruxure Power Operation with Advanced Reports: 2021 - 2022
EcoStruxure Power SCADA Operation with Advanced Reports: All versions
External links
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-254-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-254-02.pdf
https://www.cisa.gov/news-events/ics-advisories/icsa-25-014-03
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote authenticated user via the Internet.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.