Vulnerability identifier: #VU15300
Vulnerability risk: Low
CVSSv3.1: 6.3 [CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C]
CVE-ID:
CWE-ID:
CWE-269
Exploitation vector: Network
Exploit availability: No
Vulnerable software:
ROX II
Server applications /
SCADA systems
Vendor: Siemens
Description
The vulnerability allows a remote high-privileged attacker to execute arbitrary commands with elevated privileges on the target system.
The vulnerability exists due to improper privilege management. A remote attacker with a high-privileged user account access via SSH interface in on Port 22/TCP can circumvent restrictions and execute arbitrary operating system commands.
Mitigation
Update to version 2.12.1.
Vulnerable software versions
ROX II: All versions
External links
http://cert-portal.siemens.com/productcert/pdf/ssa-493830.pdf
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote authenticated privileged user via the Internet.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.