#VU16507 Privilege escalation in Siemens products - CVE-2018-11460
Published: December 12, 2018
SINUMERIK 808D
SINUMERIK 840D
SINUMERIK 828D
Siemens
Description
The vulnerability allows a local attacker to gain elevated privileges on the target system.
The vulnerability exists due to protection mechanism failure. A local attacker can modify a CRAMFS archive so that after reboot, the system loads the modified CRAMFS file that can execute arbitrary code with root privileges.
Successful exploitation of this vulnerability may result in complete compromise of vulnerable system.
Remediation
Update SINUMERIK 840D to version 4.7 SP6 HF5 or 4.8 SP3.