Vulnerability identifier: #VU16509
Vulnerability risk: Low
CVSSv3.1: 8.5 [CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C]
CVE-ID:
CWE-ID:
CWE-264
Exploitation vector: Network
Exploit availability: No
Vulnerable software:
SINUMERIK 808D
Hardware solutions /
Firmware
SINUMERIK 840D
Hardware solutions /
Firmware
SINUMERIK 828D
Server applications /
SCADA systems
Vendor: Siemens
Description
The vulnerability allows a remote unauthenticated attacker to gain elevated privileges on the target system.
The vulnerability exists due to improper privileges and access controls. A remote attacker can send a specially crafted authentication request and gain elevated privileges.
Mitigation
Update SINUMERIK 828D to version 4.7 SP6 HF1.
Update SINUMERIK 840D to version 4.7 SP6 HF5 or 4.8 SP3.
Vulnerable software versions
SINUMERIK 808D: All versions
SINUMERIK 828D: All versions
SINUMERIK 840D: All versions
External links
http://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the Internet.
Is there known malware, which exploits this vulnerability?