Vulnerability identifier: #VU16511
Vulnerability risk: Low
CVSSv3.1: 4.6 [CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:U/RL:O/RC:C]
CVE-ID:
CWE-ID:
CWE-248
Exploitation vector: Network
Exploit availability: No
Vulnerable software:
SINUMERIK 808D
Hardware solutions /
Firmware
SINUMERIK 840D
Hardware solutions /
Firmware
SINUMERIK 828D
Server applications /
SCADA systems
Vendor: Siemens
Description
The vulnerability allows a remote attacker to cause DoS condition on the target system.
The vulnerability exists due to uncaught exception if Port 5900/TCP is manually opened in the firewall configuration of network Port X130. A remote unauthenticated attacker can cause a denial-of-service condition of the VNC server.
Mitigation
Update SINUMERIK 828D to version 4.7 SP6 HF1.
Update SINUMERIK 840D to version 4.7 SP6 HF5 or 4.8 SP3.
Vulnerable software versions
SINUMERIK 808D: All versions
SINUMERIK 828D: All versions
SINUMERIK 840D: All versions
External links
http://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the Internet.
Is there known malware, which exploits this vulnerability?