Vulnerability identifier: #VU42897
Vulnerability risk: Medium
CVSSv3.1: 6.5 [CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:U/RL:O/RC:C]
CVE-ID:
CWE-ID:
CWE-20
Exploitation vector: Network
Exploit availability: No
Vulnerable software:
FactoryTalk Services Platform
Client/Desktop applications /
Other client software
Vendor: Rockwell Automation
Description
The vulnerability allows a remote non-authenticated attacker to perform a denial of service (DoS) attack.
Integer overflow in RNADiagnostics.dll in Rockwell Automation FactoryTalk Services Platform (FTSP) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (service outage or RNADiagReceiver.exe daemon crash) via UDP data that specifies a large integer value.
Mitigation
Install update from vendor's website.
Vulnerable software versions
FactoryTalk Services Platform: cpr9
External links
http://ics-cert.us-cert.gov/pdf/ICSA-13-095-02.pdf
http://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the Internet.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.