Vulnerability identifier: #VU56142
Vulnerability risk: High
CVSSv3.1: 8.5 [CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C]
CVE-ID:
CWE-ID:
CWE-89
Exploitation vector: Network
Exploit availability: No
Vulnerable software:
Tasy Electronic Medical Record
Server applications /
Other server solutions
Vendor: Philips
Description
The vulnerability allows a remote attacker to execute arbitrary SQL queries in database.
The vulnerability exists due to insufficient sanitization of user-supplied data in the "FilterValue" parameter in "WAdvancedFilter/getDimensionItemsByCode". A remote attacker can send a specially crafted request to the affected application and execute arbitrary SQL commands within the application database.
Successful exploitation of this vulnerability may allow a remote attacker to read, delete, modify data in database and gain complete control over the affected application.
Mitigation
Install update from vendor's website.
Vulnerable software versions
Tasy Electronic Medical Record: 3.06.1803
External links
http://br.linkedin.com/in/felippe-foppa-6b1434108
http://diesec.home.blog/2021/08/24/philips-tasy-emr-3-06-sql-injection-cve-2021-39375cve-2021-39376/
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the Internet.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.