#VU56143 SQL injection in Tasy Electronic Medical Record - CVE-2021-39376

 

#VU56143 SQL injection in Tasy Electronic Medical Record - CVE-2021-39376

Published: August 27, 2021 / Updated: November 8, 2021


Vulnerability identifier: #VU56143
Vulnerability risk: High
CVSSv4.0: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/U:Amber
CVE-ID: CVE-2021-39376
CWE-ID: CWE-89
Exploitation vector: Remote access
Exploit availability: No public exploit available
Vulnerable software:
Tasy Electronic Medical Record
Software vendor:
Philips

Description

The vulnerability allows a remote attacker to execute arbitrary SQL queries in database.

The vulnerability exists due to insufficient sanitization of user-supplied data in the "IE_CORPO_ASSIST" or "CD_USUARIO_CONVENIO" parameters in "CorCad_F2/executaConsultaEspecifico". A remote attacker can send a specially crafted request to the affected application and execute arbitrary SQL commands within the application database.

Successful exploitation of this vulnerability may allow a remote attacker to read, delete, modify data in database and gain complete control over the affected application.


Remediation

Install update from vendor's website.