Vulnerability identifier: #VU57189
Vulnerability risk: Medium
CVSSv3.1: 7.7 [CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C]
CVE-ID:
CWE-ID:
CWE-284
Exploitation vector: Local network
Exploit availability: No
Vulnerable software:
MiR100
Hardware solutions /
Firmware
MiR200
Hardware solutions /
Firmware
MiR250
Hardware solutions /
Firmware
MiR500
Hardware solutions /
Firmware
MiR1000
Hardware solutions /
Firmware
MiR Fleet
Hardware solutions /
Firmware
Vendor: Mobile Industrial Robots
Description
The vulnerability allows a remote attacker to gain unauthorized access to otherwise restricted functionality.
The vulnerability exists due to MiR robots shipped before June 2020 had default passwords set for the SICK safety PLC. A remote attacker on the local network can use the default credentials to manipulate the safety PLC, effectively disabling the emergency stop function.
Mitigation
Install updates from vendor's website.
Vulnerable software versions
MiR100: All versions
MiR200: All versions
MiR250: All versions
MiR500: All versions
MiR1000: All versions
MiR Fleet: All versions
External links
http://us-cert.cisa.gov/ics/advisories/icsa-21-280-02
http://github.com/aliasrobotics/RVD/issues/2558
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the local network (LAN).
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.