Vulnerability identifier: #VU61906
Vulnerability risk: Medium
CVSSv3.1: 5.7 [CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:U/RL:O/RC:C]
CVE-ID:
CWE-ID:
CWE-288
Exploitation vector: Network
Exploit availability: No
Vulnerable software:
Patient Portal
Web applications /
Other software
Vendor: Lifepoint Informatics
Description
The vulnerability allows a remote attacker to bypass authentication process.
The vulnerability exists due to an error in when processing authentication requests. A remote user can cause the server to generate a PDF of a lab report without authentication and rate limiting.
Mitigation
Install updates from vendor's website.
Vulnerable software versions
Patient Portal: 3.5.12.P30
External links
http://ics-cert.us-cert.gov/advisories/icsma-22-095-01
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote authenticated user via the Internet.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.