Vulnerability identifier: #VU65802
Vulnerability risk: Low
CVSSv3.1: 5.9 [CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N/E:U/RL:O/RC:C]
CVE-ID:
CWE-ID:
CWE-611
Exploitation vector: Network
Exploit availability: No
Vulnerable software:
Ignition
Server applications /
SCADA systems
Vendor: Inductive Automation
Description
The vulnerability allows a remote user to gain access to sensitive information.
The vulnerability exists due to insufficient validation of user-supplied XML input in the backup/restore functionality. A remote administrator can pass a specially crafted XML code to the affected application and view contents of arbitrary files on the system or initiate requests to external systems.
Successful exploitation of the vulnerability may allow an attacker to view contents of arbitrary file on the server or perform network scanning of internal and external infrastructure.
Mitigation
Install updates from vendor's website.
Vulnerable software versions
Ignition: 7.9.0 - 8.1.8
External links
http://ics-cert.us-cert.gov/advisories/icsa-22-207-01
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote authenticated privileged user via the Internet.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.