Vulnerability identifier: #VU88481
Vulnerability risk: Low
CVSSv3.1: 5.4 [CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:U/RL:O/RC:C]
CVE-ID:
CWE-ID:
CWE-119
Exploitation vector: Local
Exploit availability: No
Vulnerable software:
SIMATIC PCS 7
Server applications /
SCADA systems
SIMATIC WinCC Runtime Professional
Server applications /
SCADA systems
Siemens SIMATIC WinCC
Server applications /
SCADA systems
Vendor: Siemens
Description
The vulnerability allows a local attacker to perform a denial of service (DoS) attack.
The vulnerability exists due to a boundary error in the login dialog box. A local attacker can trigger memory corruption and cause a denial of service condition on the target system.
Mitigation
Install updates from vendor's website.
Vulnerable software versions
SIMATIC PCS 7: 9.1
SIMATIC WinCC Runtime Professional: 17.0 - 19.0
Siemens SIMATIC WinCC: 7.5 - 8.0
External links
http://cert-portal.siemens.com/productcert/html/ssa-730482.html
Can this vulnerability be exploited remotely?
No. This vulnerability can be exploited locally. The attacker should have authentication credentials and successfully authenticate on the system.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.