Risk | Medium |
Patch available | YES |
Number of vulnerabilities | 9 |
CVE-ID | CVE-2023-45229 CVE-2023-45230 CVE-2023-45231 CVE-2023-45232 CVE-2023-45233 CVE-2023-45234 CVE-2023-45235 CVE-2023-45236 CVE-2023-45237 |
CWE-ID | CWE-125 CWE-119 CWE-835 CWE-338 |
Exploitation vector | Network |
Public exploit | N/A |
Vulnerable software |
Dell EMC Storage NX3240 Hardware solutions / Firmware PowerEdge R730xd Hardware solutions / Firmware PowerEdge R630 Hardware solutions / Firmware PowerEdge C4130 Hardware solutions / Firmware PowerEdge R930 Hardware solutions / Firmware PowerEdge T630 Hardware solutions / Firmware PowerEdge R830 Hardware solutions / Firmware PowerEdge T130 Hardware solutions / Firmware PowerEdge R230 Hardware solutions / Firmware PowerEdge T330 Hardware solutions / Firmware PowerEdge R330 Hardware solutions / Firmware Dell Storage NX430 Hardware solutions / Firmware Dell Storage NX3330 Hardware solutions / Firmware Dell XC730XD Hyper-converged Appliance Hardware solutions / Firmware Dell XC730 Hyper-converged Appliance Hardware solutions / Firmware Dell XC630 Hyper-converged Appliance Hardware solutions / Firmware Dell XC430 Hyper-converged Appliance Hardware solutions / Firmware Dell XC6320 Hyper-converged Appliance Hardware solutions / Firmware Dell EMC XC Core XC7525 Hardware solutions / Firmware Dell EMC XC Core XCXR2 Hardware solutions / Firmware Dell EMC XC Core XC940 System Hardware solutions / Firmware Dell EMC XC Core XC740xd2 Hardware solutions / Firmware Dell EMC XC Core XC740xd System Hardware solutions / Firmware Dell EMC XC Core XC640 System Hardware solutions / Firmware Dell EMC XC Core 6420 System Hardware solutions / Firmware Dell EMC XC Core XC6520 Hardware solutions / Firmware Dell EMC XC Core XC750xa Hardware solutions / Firmware Dell EMC XC Core XC750 Hardware solutions / Firmware Dell EMC XC Core XC650 Hardware solutions / Firmware Dell EMC XC Core XC450 Hardware solutions / Firmware Dell XC Core XC760 Hardware solutions / Firmware Dell XC Core XC660 Hardware solutions / Firmware Dell Storage NX3230 Hardware solutions / Firmware Dell EMC NX440 Hardware solutions / Firmware Dell EMC Storage NX3340 Hardware solutions / Firmware PowerEdge C6320 Hardware solutions / Firmware PowerEdge T430 Hardware solutions / Firmware PowerEdge R430 Hardware solutions / Firmware PowerEdge R530 Hardware solutions / Firmware PowerEdge FC830 Hardware solutions / Firmware PowerEdge M830 (for PE VRTX) Hardware solutions / Firmware PowerEdge M830 Hardware solutions / Firmware PowerEdge FC430 Hardware solutions / Firmware PowerEdge FC630 Hardware solutions / Firmware PowerEdge M630 (for PE VRTX) Hardware solutions / Firmware PowerEdge M630 Hardware solutions / Firmware PowerEdge R730 Hardware solutions / Firmware PowerEdge R340 Hardware solutions / Firmware PowerEdge R240 Hardware solutions / Firmware PowerEdge T340 Hardware solutions / Firmware PowerEdge T140 Hardware solutions / Firmware PowerEdge XE7440 Hardware solutions / Firmware PowerEdge XE7420 Hardware solutions / Firmware PowerEdge XE2420 Hardware solutions / Firmware DSS 8440 Hardware solutions / Firmware PowerEdge C4140 Hardware solutions / Firmware PowerEdge MX840C Hardware solutions / Firmware PowerEdge MX740C Hardware solutions / Firmware PowerEdge M640 (for PE VRTX) Hardware solutions / Firmware PowerEdge M640 Hardware solutions / Firmware PowerEdge FC640 Hardware solutions / Firmware PowerEdge C6420 Hardware solutions / Firmware PowerEdge T640 Hardware solutions / Firmware PowerEdge R940XA Hardware solutions / Firmware PowerEdge R840 Hardware solutions / Firmware PowerEdge R740XD2 Hardware solutions / Firmware PowerEdge XR2 Hardware solutions / Firmware PowerEdge T440 Hardware solutions / Firmware PowerEdge R440 Hardware solutions / Firmware PowerEdge R540 Hardware solutions / Firmware PowerEdge R940 Hardware solutions / Firmware PowerEdge R640 Hardware solutions / Firmware PowerEdge R740XD Hardware solutions / Firmware PowerEdge R740 Hardware solutions / Firmware PowerEdge C6615 Hardware solutions / Firmware PowerEdge R7625 Hardware solutions / Firmware PowerEdge R6625 Hardware solutions / Firmware PowerEdge R7615 Hardware solutions / Firmware PowerEdge R6615 Hardware solutions / Firmware PowerEdge XE9640 Hardware solutions / Firmware PowerEdge XE8640 Hardware solutions / Firmware PowerEdge XR7620 Hardware solutions / Firmware PowerEdge XR8620t Hardware solutions / Firmware PowerEdge XR8610t Hardware solutions / Firmware PowerEdge XR5610 Hardware solutions / Firmware PowerEdge XE9680 Hardware solutions / Firmware PowerEdge R760xa Hardware solutions / Firmware PowerEdge T560 Hardware solutions / Firmware PowerEdge R760xd2 Hardware solutions / Firmware PowerEdge R760xs Hardware solutions / Firmware PowerEdge R660xs Hardware solutions / Firmware PowerEdge HS5620 Hardware solutions / Firmware PowerEdge HS5610 Hardware solutions / Firmware PowerEdge R960 Hardware solutions / Firmware PowerEdge R860 Hardware solutions / Firmware PowerEdge MX760c Hardware solutions / Firmware PowerEdge C6620 Hardware solutions / Firmware PowerEdge R760 Hardware solutions / Firmware PowerEdge R660 Hardware solutions / Firmware PowerEdge XR4520c Hardware solutions / Firmware PowerEdge XR4510c Hardware solutions / Firmware PowerEdge R350 Hardware solutions / Firmware PowerEdge R250 Hardware solutions / Firmware PowerEdge T350 Hardware solutions / Firmware PowerEdge T150 Hardware solutions / Firmware PowerEdge XR12 Hardware solutions / Firmware PowerEdge XR11 Hardware solutions / Firmware PowerEdge T550 Hardware solutions / Firmware PowerEdge R750XS Hardware solutions / Firmware PowerEdge R650XS Hardware solutions / Firmware PowerEdge R450 Hardware solutions / Firmware PowerEdge R550 Hardware solutions / Firmware PowerEdge MX750c Hardware solutions / Firmware PowerEdge C6520 Hardware solutions / Firmware PowerEdge R750XA Hardware solutions / Firmware PowerEdge R750 Hardware solutions / Firmware PowerEdge R650 Hardware solutions / Firmware PowerEdge R7425 Server applications / Other server solutions PowerEdge R7415 Server applications / Other server solutions PowerEdge R6415 Server applications / Other server solutions PowerEdge XE8545 Server applications / Other server solutions PowerEdge C6525 Server applications / Other server solutions PowerEdge R7525 Server applications / Other server solutions PowerEdge R7515 Server applications / Other server solutions PowerEdge R6525 Server applications / Other server solutions PowerEdge R6515 Server applications / Other server solutions |
Vendor | Dell |
Security Bulletin
This security bulletin contains information about 9 vulnerabilities.
EUVDB-ID: #VU85519
Risk: Low
CVSSv4.0: 4.9 [CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:U/U:Clear]
CVE-ID: CVE-2023-45229
CWE-ID:
CWE-125 - Out-of-bounds read
Exploit availability: No
DescriptionThe vulnerability allows a remote attacker to gain access to potentially sensitive information.
The vulnerability exists due to a boundary condition when processing the IA_NA or IA_TA option in a DHCPv6 Advertise message. A remote attacker on the local network can trigger an out-of-bounds read error and read contents of memory on the system.
MitigationInstall update from vendor's website.
Vulnerable software versionsDell EMC Storage NX3240: before 2.20.1
PowerEdge R730xd: before 2.18.1
PowerEdge R630: before 2.18.1
PowerEdge C4130: before 2.18.1
PowerEdge R930: before 2.13.0
PowerEdge T630: before 2.18.2
PowerEdge R830: before 1.18.1
PowerEdge T130: before 2.19.1
PowerEdge R230: before 2.19.1
PowerEdge T330: before 2.19.1
PowerEdge R330: before 2.19.1
Dell Storage NX430: before 2.19.0
Dell Storage NX3330: before 2.18.1
Dell XC730XD Hyper-converged Appliance: before 2.18.1
Dell XC730 Hyper-converged Appliance: before 2.18.1
Dell XC630 Hyper-converged Appliance: before 2.18.1
Dell XC430 Hyper-converged Appliance: before 2.18.2
Dell XC6320 Hyper-converged Appliance: before 2.18.2
Dell EMC XC Core XC7525: before 2.13.3
Dell EMC XC Core XCXR2: before 2.20.1
Dell EMC XC Core XC940 System: before 2.20.1
Dell EMC XC Core XC740xd2: before 2.20.1
Dell EMC XC Core XC740xd System: before 2.20.1
Dell EMC XC Core XC640 System: before 2.20.1
Dell EMC XC Core 6420 System: before 2.20.1
Dell EMC XC Core XC6520: before 1.12.1
Dell EMC XC Core XC750xa: before 1.12.1
Dell EMC XC Core XC750: before 1.12.1
Dell EMC XC Core XC650: before 1.12.1
Dell EMC XC Core XC450: before 1.12.1
Dell XC Core XC760: before 1.6.6
Dell XC Core XC660: before 1.6.6
Dell Storage NX3230: before 2.18.1
Dell EMC NX440: before 2.15.1
Dell EMC Storage NX3340: before 2.20.1
PowerEdge C6320: before 2.18.2
PowerEdge T430: before 2.18.2
PowerEdge R430: before 2.18.2
PowerEdge R530: before 2.18.2
PowerEdge FC830: before 2.18.1
PowerEdge M830 (for PE VRTX): before 2.18.1
PowerEdge M830: before 2.18.1
PowerEdge FC430: before 2.18.1
PowerEdge FC630: before 2.18.1
PowerEdge M630 (for PE VRTX): before 2.18.1
PowerEdge M630: before 2.18.1
PowerEdge R730: before 2.18.1
PowerEdge R7425: before 1.21.0
PowerEdge R7415: before 1.21.0
PowerEdge R6415: before 1.21.0
PowerEdge R340: before 2.15.1
PowerEdge R240: before 2.15.1
PowerEdge T340: before 2.15.1
PowerEdge T140: before 2.15.1
PowerEdge XE7440: before 2.20.0
PowerEdge XE7420: before 2.20.0
PowerEdge XE2420: before 2.20.0
DSS 8440: before 2.20.0
PowerEdge C4140: before 2.20.1
PowerEdge MX840C: before 2.20.1
PowerEdge MX740C: before 2.20.1
PowerEdge M640 (for PE VRTX): before 2.20.1
PowerEdge M640: before 2.20.1
PowerEdge FC640: before 2.20.1
PowerEdge C6420: before 2.20.1
PowerEdge T640: before 2.20.1
PowerEdge R940XA: before 2.20.1
PowerEdge R840: before 2.20.1
PowerEdge R740XD2: before 2.20.1
PowerEdge XR2: before 2.20.1
PowerEdge T440: before 2.20.1
PowerEdge R440: before 2.20.1
PowerEdge R540: before 2.20.1
PowerEdge R940: before 2.20.1
PowerEdge R640: before 2.20.1
PowerEdge R740XD: before 2.20.1
PowerEdge R740: before 2.20.1
PowerEdge XE8545: before 2.13.3
PowerEdge C6525: before 2.13.3
PowerEdge R7525: before 2.13.3
PowerEdge R7515: before 2.13.3
PowerEdge R6525: before 2.13.3
PowerEdge R6515: before 2.13.3
PowerEdge C6615: before 1.1.2
PowerEdge R7625: before 1.6.8
PowerEdge R6625: before 1.6.8
PowerEdge R7615: before 1.6.6
PowerEdge R6615: before 1.6.6
PowerEdge XE9640: before 1.3.6
PowerEdge XE8640: before 1.3.6
PowerEdge XR7620: before 1.6.6
PowerEdge XR8620t: before 1.6.6
PowerEdge XR8610t: before 1.6.6
PowerEdge XR5610: before 1.6.6
PowerEdge XE9680: before 1.3.6
PowerEdge R760xa: before 1.6.6
PowerEdge T560: before 1.6.6
PowerEdge R760xd2: before 1.6.6
PowerEdge R760xs: before 1.6.6
PowerEdge R660xs: before 1.6.6
PowerEdge HS5620: before 1.6.6
PowerEdge HS5610: before 1.6.6
PowerEdge R960: before 1.6.6
PowerEdge R860: before 1.6.6
PowerEdge MX760c: before 1.6.6
PowerEdge C6620: before 1.6.6
PowerEdge R760: before 1.6.6
PowerEdge R660: before 1.6.6
PowerEdge XR4520c: before 1.13.3
PowerEdge XR4510c: before 1.13.3
PowerEdge R350: before 1.8.1
PowerEdge R250: before 1.8.1
PowerEdge T350: before 1.8.1
PowerEdge T150: before 1.8.1
PowerEdge XR12: before 1.12.1
PowerEdge XR11: before 1.12.1
PowerEdge T550: before 1.12.1
PowerEdge R750XS: before 1.12.1
PowerEdge R650XS: before 1.12.1
PowerEdge R450: before 1.12.1
PowerEdge R550: before 1.12.1
PowerEdge MX750c: before 1.12.1
PowerEdge C6520: before 1.12.1
PowerEdge R750XA: before 1.12.1
PowerEdge R750: before 1.12.1
PowerEdge R650: before 1.12.1
CPE2.3Q & A
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the local network (LAN).
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.
EUVDB-ID: #VU85520
Risk: Medium
CVSSv4.0: 6.3 [CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/U:Green]
CVE-ID: CVE-2023-45230
CWE-ID:
CWE-119 - Memory corruption
Exploit availability: No
DescriptionThe vulnerability allows a remote attacker to execute arbitrary code on the target system.
The vulnerability exists due to a boundary within a long server ID option in DHCPv6 client. A remote attacker on the local network can trigger memory corruption and execute arbitrary code on the target system.
Successful exploitation of this vulnerability may result in complete compromise of vulnerable system.
MitigationInstall update from vendor's website.
Vulnerable software versionsDell EMC Storage NX3240: before 2.20.1
PowerEdge R730xd: before 2.18.1
PowerEdge R630: before 2.18.1
PowerEdge C4130: before 2.18.1
PowerEdge R930: before 2.13.0
PowerEdge T630: before 2.18.2
PowerEdge R830: before 1.18.1
PowerEdge T130: before 2.19.1
PowerEdge R230: before 2.19.1
PowerEdge T330: before 2.19.1
PowerEdge R330: before 2.19.1
Dell Storage NX430: before 2.19.0
Dell Storage NX3330: before 2.18.1
Dell XC730XD Hyper-converged Appliance: before 2.18.1
Dell XC730 Hyper-converged Appliance: before 2.18.1
Dell XC630 Hyper-converged Appliance: before 2.18.1
Dell XC430 Hyper-converged Appliance: before 2.18.2
Dell XC6320 Hyper-converged Appliance: before 2.18.2
Dell EMC XC Core XC7525: before 2.13.3
Dell EMC XC Core XCXR2: before 2.20.1
Dell EMC XC Core XC940 System: before 2.20.1
Dell EMC XC Core XC740xd2: before 2.20.1
Dell EMC XC Core XC740xd System: before 2.20.1
Dell EMC XC Core XC640 System: before 2.20.1
Dell EMC XC Core 6420 System: before 2.20.1
Dell EMC XC Core XC6520: before 1.12.1
Dell EMC XC Core XC750xa: before 1.12.1
Dell EMC XC Core XC750: before 1.12.1
Dell EMC XC Core XC650: before 1.12.1
Dell EMC XC Core XC450: before 1.12.1
Dell XC Core XC760: before 1.6.6
Dell XC Core XC660: before 1.6.6
Dell Storage NX3230: before 2.18.1
Dell EMC NX440: before 2.15.1
Dell EMC Storage NX3340: before 2.20.1
PowerEdge C6320: before 2.18.2
PowerEdge T430: before 2.18.2
PowerEdge R430: before 2.18.2
PowerEdge R530: before 2.18.2
PowerEdge FC830: before 2.18.1
PowerEdge M830 (for PE VRTX): before 2.18.1
PowerEdge M830: before 2.18.1
PowerEdge FC430: before 2.18.1
PowerEdge FC630: before 2.18.1
PowerEdge M630 (for PE VRTX): before 2.18.1
PowerEdge M630: before 2.18.1
PowerEdge R730: before 2.18.1
PowerEdge R7425: before 1.21.0
PowerEdge R7415: before 1.21.0
PowerEdge R6415: before 1.21.0
PowerEdge R340: before 2.15.1
PowerEdge R240: before 2.15.1
PowerEdge T340: before 2.15.1
PowerEdge T140: before 2.15.1
PowerEdge XE7440: before 2.20.0
PowerEdge XE7420: before 2.20.0
PowerEdge XE2420: before 2.20.0
DSS 8440: before 2.20.0
PowerEdge C4140: before 2.20.1
PowerEdge MX840C: before 2.20.1
PowerEdge MX740C: before 2.20.1
PowerEdge M640 (for PE VRTX): before 2.20.1
PowerEdge M640: before 2.20.1
PowerEdge FC640: before 2.20.1
PowerEdge C6420: before 2.20.1
PowerEdge T640: before 2.20.1
PowerEdge R940XA: before 2.20.1
PowerEdge R840: before 2.20.1
PowerEdge R740XD2: before 2.20.1
PowerEdge XR2: before 2.20.1
PowerEdge T440: before 2.20.1
PowerEdge R440: before 2.20.1
PowerEdge R540: before 2.20.1
PowerEdge R940: before 2.20.1
PowerEdge R640: before 2.20.1
PowerEdge R740XD: before 2.20.1
PowerEdge R740: before 2.20.1
PowerEdge XE8545: before 2.13.3
PowerEdge C6525: before 2.13.3
PowerEdge R7525: before 2.13.3
PowerEdge R7515: before 2.13.3
PowerEdge R6525: before 2.13.3
PowerEdge R6515: before 2.13.3
PowerEdge C6615: before 1.1.2
PowerEdge R7625: before 1.6.8
PowerEdge R6625: before 1.6.8
PowerEdge R7615: before 1.6.6
PowerEdge R6615: before 1.6.6
PowerEdge XE9640: before 1.3.6
PowerEdge XE8640: before 1.3.6
PowerEdge XR7620: before 1.6.6
PowerEdge XR8620t: before 1.6.6
PowerEdge XR8610t: before 1.6.6
PowerEdge XR5610: before 1.6.6
PowerEdge XE9680: before 1.3.6
PowerEdge R760xa: before 1.6.6
PowerEdge T560: before 1.6.6
PowerEdge R760xd2: before 1.6.6
PowerEdge R760xs: before 1.6.6
PowerEdge R660xs: before 1.6.6
PowerEdge HS5620: before 1.6.6
PowerEdge HS5610: before 1.6.6
PowerEdge R960: before 1.6.6
PowerEdge R860: before 1.6.6
PowerEdge MX760c: before 1.6.6
PowerEdge C6620: before 1.6.6
PowerEdge R760: before 1.6.6
PowerEdge R660: before 1.6.6
PowerEdge XR4520c: before 1.13.3
PowerEdge XR4510c: before 1.13.3
PowerEdge R350: before 1.8.1
PowerEdge R250: before 1.8.1
PowerEdge T350: before 1.8.1
PowerEdge T150: before 1.8.1
PowerEdge XR12: before 1.12.1
PowerEdge XR11: before 1.12.1
PowerEdge T550: before 1.12.1
PowerEdge R750XS: before 1.12.1
PowerEdge R650XS: before 1.12.1
PowerEdge R450: before 1.12.1
PowerEdge R550: before 1.12.1
PowerEdge MX750c: before 1.12.1
PowerEdge C6520: before 1.12.1
PowerEdge R750XA: before 1.12.1
PowerEdge R750: before 1.12.1
PowerEdge R650: before 1.12.1
CPE2.3Q & A
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the local network (LAN).
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.
EUVDB-ID: #VU85521
Risk: Low
CVSSv4.0: 4.9 [CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:U/U:Clear]
CVE-ID: CVE-2023-45231
CWE-ID:
CWE-125 - Out-of-bounds read
Exploit availability: No
DescriptionThe vulnerability allows a remote attacker to gain access to potentially sensitive information.
The vulnerability exists due to a boundary condition when processing Neighbor Discovery Redirect message. A remote attacker on the local network can trigger an out-of-bounds read error and read contents of memory on the system.
MitigationInstall update from vendor's website.
Vulnerable software versionsDell EMC Storage NX3240: before 2.20.1
PowerEdge R730xd: before 2.18.1
PowerEdge R630: before 2.18.1
PowerEdge C4130: before 2.18.1
PowerEdge R930: before 2.13.0
PowerEdge T630: before 2.18.2
PowerEdge R830: before 1.18.1
PowerEdge T130: before 2.19.1
PowerEdge R230: before 2.19.1
PowerEdge T330: before 2.19.1
PowerEdge R330: before 2.19.1
Dell Storage NX430: before 2.19.0
Dell Storage NX3330: before 2.18.1
Dell XC730XD Hyper-converged Appliance: before 2.18.1
Dell XC730 Hyper-converged Appliance: before 2.18.1
Dell XC630 Hyper-converged Appliance: before 2.18.1
Dell XC430 Hyper-converged Appliance: before 2.18.2
Dell XC6320 Hyper-converged Appliance: before 2.18.2
Dell EMC XC Core XC7525: before 2.13.3
Dell EMC XC Core XCXR2: before 2.20.1
Dell EMC XC Core XC940 System: before 2.20.1
Dell EMC XC Core XC740xd2: before 2.20.1
Dell EMC XC Core XC740xd System: before 2.20.1
Dell EMC XC Core XC640 System: before 2.20.1
Dell EMC XC Core 6420 System: before 2.20.1
Dell EMC XC Core XC6520: before 1.12.1
Dell EMC XC Core XC750xa: before 1.12.1
Dell EMC XC Core XC750: before 1.12.1
Dell EMC XC Core XC650: before 1.12.1
Dell EMC XC Core XC450: before 1.12.1
Dell XC Core XC760: before 1.6.6
Dell XC Core XC660: before 1.6.6
Dell Storage NX3230: before 2.18.1
Dell EMC NX440: before 2.15.1
Dell EMC Storage NX3340: before 2.20.1
PowerEdge C6320: before 2.18.2
PowerEdge T430: before 2.18.2
PowerEdge R430: before 2.18.2
PowerEdge R530: before 2.18.2
PowerEdge FC830: before 2.18.1
PowerEdge M830 (for PE VRTX): before 2.18.1
PowerEdge M830: before 2.18.1
PowerEdge FC430: before 2.18.1
PowerEdge FC630: before 2.18.1
PowerEdge M630 (for PE VRTX): before 2.18.1
PowerEdge M630: before 2.18.1
PowerEdge R730: before 2.18.1
PowerEdge R7425: before 1.21.0
PowerEdge R7415: before 1.21.0
PowerEdge R6415: before 1.21.0
PowerEdge R340: before 2.15.1
PowerEdge R240: before 2.15.1
PowerEdge T340: before 2.15.1
PowerEdge T140: before 2.15.1
PowerEdge XE7440: before 2.20.0
PowerEdge XE7420: before 2.20.0
PowerEdge XE2420: before 2.20.0
DSS 8440: before 2.20.0
PowerEdge C4140: before 2.20.1
PowerEdge MX840C: before 2.20.1
PowerEdge MX740C: before 2.20.1
PowerEdge M640 (for PE VRTX): before 2.20.1
PowerEdge M640: before 2.20.1
PowerEdge FC640: before 2.20.1
PowerEdge C6420: before 2.20.1
PowerEdge T640: before 2.20.1
PowerEdge R940XA: before 2.20.1
PowerEdge R840: before 2.20.1
PowerEdge R740XD2: before 2.20.1
PowerEdge XR2: before 2.20.1
PowerEdge T440: before 2.20.1
PowerEdge R440: before 2.20.1
PowerEdge R540: before 2.20.1
PowerEdge R940: before 2.20.1
PowerEdge R640: before 2.20.1
PowerEdge R740XD: before 2.20.1
PowerEdge R740: before 2.20.1
PowerEdge XE8545: before 2.13.3
PowerEdge C6525: before 2.13.3
PowerEdge R7525: before 2.13.3
PowerEdge R7515: before 2.13.3
PowerEdge R6525: before 2.13.3
PowerEdge R6515: before 2.13.3
PowerEdge C6615: before 1.1.2
PowerEdge R7625: before 1.6.8
PowerEdge R6625: before 1.6.8
PowerEdge R7615: before 1.6.6
PowerEdge R6615: before 1.6.6
PowerEdge XE9640: before 1.3.6
PowerEdge XE8640: before 1.3.6
PowerEdge XR7620: before 1.6.6
PowerEdge XR8620t: before 1.6.6
PowerEdge XR8610t: before 1.6.6
PowerEdge XR5610: before 1.6.6
PowerEdge XE9680: before 1.3.6
PowerEdge R760xa: before 1.6.6
PowerEdge T560: before 1.6.6
PowerEdge R760xd2: before 1.6.6
PowerEdge R760xs: before 1.6.6
PowerEdge R660xs: before 1.6.6
PowerEdge HS5620: before 1.6.6
PowerEdge HS5610: before 1.6.6
PowerEdge R960: before 1.6.6
PowerEdge R860: before 1.6.6
PowerEdge MX760c: before 1.6.6
PowerEdge C6620: before 1.6.6
PowerEdge R760: before 1.6.6
PowerEdge R660: before 1.6.6
PowerEdge XR4520c: before 1.13.3
PowerEdge XR4510c: before 1.13.3
PowerEdge R350: before 1.8.1
PowerEdge R250: before 1.8.1
PowerEdge T350: before 1.8.1
PowerEdge T150: before 1.8.1
PowerEdge XR12: before 1.12.1
PowerEdge XR11: before 1.12.1
PowerEdge T550: before 1.12.1
PowerEdge R750XS: before 1.12.1
PowerEdge R650XS: before 1.12.1
PowerEdge R450: before 1.12.1
PowerEdge R550: before 1.12.1
PowerEdge MX750c: before 1.12.1
PowerEdge C6520: before 1.12.1
PowerEdge R750XA: before 1.12.1
PowerEdge R750: before 1.12.1
PowerEdge R650: before 1.12.1
CPE2.3Q & A
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the local network (LAN).
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.
EUVDB-ID: #VU85522
Risk: Medium
CVSSv4.0: 6.6 [CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:U/U:Green]
CVE-ID: CVE-2023-45232
CWE-ID:
CWE-835 - Loop with Unreachable Exit Condition ('Infinite Loop')
Exploit availability: No
DescriptionThe vulnerability allows a remote attacker to perform a denial of service (DoS) attack.
The vulnerability exists due to infinite loop when parsing unknown options in the Destination Options header of IPv6. A remote attacker can consume all available system resources and cause denial of service conditions.
MitigationInstall update from vendor's website.
Vulnerable software versionsDell EMC Storage NX3240: before 2.20.1
PowerEdge R730xd: before 2.18.1
PowerEdge R630: before 2.18.1
PowerEdge C4130: before 2.18.1
PowerEdge R930: before 2.13.0
PowerEdge T630: before 2.18.2
PowerEdge R830: before 1.18.1
PowerEdge T130: before 2.19.1
PowerEdge R230: before 2.19.1
PowerEdge T330: before 2.19.1
PowerEdge R330: before 2.19.1
Dell Storage NX430: before 2.19.0
Dell Storage NX3330: before 2.18.1
Dell XC730XD Hyper-converged Appliance: before 2.18.1
Dell XC730 Hyper-converged Appliance: before 2.18.1
Dell XC630 Hyper-converged Appliance: before 2.18.1
Dell XC430 Hyper-converged Appliance: before 2.18.2
Dell XC6320 Hyper-converged Appliance: before 2.18.2
Dell EMC XC Core XC7525: before 2.13.3
Dell EMC XC Core XCXR2: before 2.20.1
Dell EMC XC Core XC940 System: before 2.20.1
Dell EMC XC Core XC740xd2: before 2.20.1
Dell EMC XC Core XC740xd System: before 2.20.1
Dell EMC XC Core XC640 System: before 2.20.1
Dell EMC XC Core 6420 System: before 2.20.1
Dell EMC XC Core XC6520: before 1.12.1
Dell EMC XC Core XC750xa: before 1.12.1
Dell EMC XC Core XC750: before 1.12.1
Dell EMC XC Core XC650: before 1.12.1
Dell EMC XC Core XC450: before 1.12.1
Dell XC Core XC760: before 1.6.6
Dell XC Core XC660: before 1.6.6
Dell Storage NX3230: before 2.18.1
Dell EMC NX440: before 2.15.1
Dell EMC Storage NX3340: before 2.20.1
PowerEdge C6320: before 2.18.2
PowerEdge T430: before 2.18.2
PowerEdge R430: before 2.18.2
PowerEdge R530: before 2.18.2
PowerEdge FC830: before 2.18.1
PowerEdge M830 (for PE VRTX): before 2.18.1
PowerEdge M830: before 2.18.1
PowerEdge FC430: before 2.18.1
PowerEdge FC630: before 2.18.1
PowerEdge M630 (for PE VRTX): before 2.18.1
PowerEdge M630: before 2.18.1
PowerEdge R730: before 2.18.1
PowerEdge R7425: before 1.21.0
PowerEdge R7415: before 1.21.0
PowerEdge R6415: before 1.21.0
PowerEdge R340: before 2.15.1
PowerEdge R240: before 2.15.1
PowerEdge T340: before 2.15.1
PowerEdge T140: before 2.15.1
PowerEdge XE7440: before 2.20.0
PowerEdge XE7420: before 2.20.0
PowerEdge XE2420: before 2.20.0
DSS 8440: before 2.20.0
PowerEdge C4140: before 2.20.1
PowerEdge MX840C: before 2.20.1
PowerEdge MX740C: before 2.20.1
PowerEdge M640 (for PE VRTX): before 2.20.1
PowerEdge M640: before 2.20.1
PowerEdge FC640: before 2.20.1
PowerEdge C6420: before 2.20.1
PowerEdge T640: before 2.20.1
PowerEdge R940XA: before 2.20.1
PowerEdge R840: before 2.20.1
PowerEdge R740XD2: before 2.20.1
PowerEdge XR2: before 2.20.1
PowerEdge T440: before 2.20.1
PowerEdge R440: before 2.20.1
PowerEdge R540: before 2.20.1
PowerEdge R940: before 2.20.1
PowerEdge R640: before 2.20.1
PowerEdge R740XD: before 2.20.1
PowerEdge R740: before 2.20.1
PowerEdge XE8545: before 2.13.3
PowerEdge C6525: before 2.13.3
PowerEdge R7525: before 2.13.3
PowerEdge R7515: before 2.13.3
PowerEdge R6525: before 2.13.3
PowerEdge R6515: before 2.13.3
PowerEdge C6615: before 1.1.2
PowerEdge R7625: before 1.6.8
PowerEdge R6625: before 1.6.8
PowerEdge R7615: before 1.6.6
PowerEdge R6615: before 1.6.6
PowerEdge XE9640: before 1.3.6
PowerEdge XE8640: before 1.3.6
PowerEdge XR7620: before 1.6.6
PowerEdge XR8620t: before 1.6.6
PowerEdge XR8610t: before 1.6.6
PowerEdge XR5610: before 1.6.6
PowerEdge XE9680: before 1.3.6
PowerEdge R760xa: before 1.6.6
PowerEdge T560: before 1.6.6
PowerEdge R760xd2: before 1.6.6
PowerEdge R760xs: before 1.6.6
PowerEdge R660xs: before 1.6.6
PowerEdge HS5620: before 1.6.6
PowerEdge HS5610: before 1.6.6
PowerEdge R960: before 1.6.6
PowerEdge R860: before 1.6.6
PowerEdge MX760c: before 1.6.6
PowerEdge C6620: before 1.6.6
PowerEdge R760: before 1.6.6
PowerEdge R660: before 1.6.6
PowerEdge XR4520c: before 1.13.3
PowerEdge XR4510c: before 1.13.3
PowerEdge R350: before 1.8.1
PowerEdge R250: before 1.8.1
PowerEdge T350: before 1.8.1
PowerEdge T150: before 1.8.1
PowerEdge XR12: before 1.12.1
PowerEdge XR11: before 1.12.1
PowerEdge T550: before 1.12.1
PowerEdge R750XS: before 1.12.1
PowerEdge R650XS: before 1.12.1
PowerEdge R450: before 1.12.1
PowerEdge R550: before 1.12.1
PowerEdge MX750c: before 1.12.1
PowerEdge C6520: before 1.12.1
PowerEdge R750XA: before 1.12.1
PowerEdge R750: before 1.12.1
PowerEdge R650: before 1.12.1
CPE2.3Q & A
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the Internet.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.
EUVDB-ID: #VU85523
Risk: Medium
CVSSv4.0: 6.6 [CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:U/U:Green]
CVE-ID: CVE-2023-45233
CWE-ID:
CWE-835 - Loop with Unreachable Exit Condition ('Infinite Loop')
Exploit availability: No
DescriptionThe vulnerability allows a remote attacker to perform a denial of service (DoS) attack.
The vulnerability exists due to infinite loop when parsing a PadN option in the Destination Options header of IPv6. A remote attacker can consume all available system resources and cause denial of service conditions.
MitigationInstall update from vendor's website.
Vulnerable software versionsDell EMC Storage NX3240: before 2.20.1
PowerEdge R730xd: before 2.18.1
PowerEdge R630: before 2.18.1
PowerEdge C4130: before 2.18.1
PowerEdge R930: before 2.13.0
PowerEdge T630: before 2.18.2
PowerEdge R830: before 1.18.1
PowerEdge T130: before 2.19.1
PowerEdge R230: before 2.19.1
PowerEdge T330: before 2.19.1
PowerEdge R330: before 2.19.1
Dell Storage NX430: before 2.19.0
Dell Storage NX3330: before 2.18.1
Dell XC730XD Hyper-converged Appliance: before 2.18.1
Dell XC730 Hyper-converged Appliance: before 2.18.1
Dell XC630 Hyper-converged Appliance: before 2.18.1
Dell XC430 Hyper-converged Appliance: before 2.18.2
Dell XC6320 Hyper-converged Appliance: before 2.18.2
Dell EMC XC Core XC7525: before 2.13.3
Dell EMC XC Core XCXR2: before 2.20.1
Dell EMC XC Core XC940 System: before 2.20.1
Dell EMC XC Core XC740xd2: before 2.20.1
Dell EMC XC Core XC740xd System: before 2.20.1
Dell EMC XC Core XC640 System: before 2.20.1
Dell EMC XC Core 6420 System: before 2.20.1
Dell EMC XC Core XC6520: before 1.12.1
Dell EMC XC Core XC750xa: before 1.12.1
Dell EMC XC Core XC750: before 1.12.1
Dell EMC XC Core XC650: before 1.12.1
Dell EMC XC Core XC450: before 1.12.1
Dell XC Core XC760: before 1.6.6
Dell XC Core XC660: before 1.6.6
Dell Storage NX3230: before 2.18.1
Dell EMC NX440: before 2.15.1
Dell EMC Storage NX3340: before 2.20.1
PowerEdge C6320: before 2.18.2
PowerEdge T430: before 2.18.2
PowerEdge R430: before 2.18.2
PowerEdge R530: before 2.18.2
PowerEdge FC830: before 2.18.1
PowerEdge M830 (for PE VRTX): before 2.18.1
PowerEdge M830: before 2.18.1
PowerEdge FC430: before 2.18.1
PowerEdge FC630: before 2.18.1
PowerEdge M630 (for PE VRTX): before 2.18.1
PowerEdge M630: before 2.18.1
PowerEdge R730: before 2.18.1
PowerEdge R7425: before 1.21.0
PowerEdge R7415: before 1.21.0
PowerEdge R6415: before 1.21.0
PowerEdge R340: before 2.15.1
PowerEdge R240: before 2.15.1
PowerEdge T340: before 2.15.1
PowerEdge T140: before 2.15.1
PowerEdge XE7440: before 2.20.0
PowerEdge XE7420: before 2.20.0
PowerEdge XE2420: before 2.20.0
DSS 8440: before 2.20.0
PowerEdge C4140: before 2.20.1
PowerEdge MX840C: before 2.20.1
PowerEdge MX740C: before 2.20.1
PowerEdge M640 (for PE VRTX): before 2.20.1
PowerEdge M640: before 2.20.1
PowerEdge FC640: before 2.20.1
PowerEdge C6420: before 2.20.1
PowerEdge T640: before 2.20.1
PowerEdge R940XA: before 2.20.1
PowerEdge R840: before 2.20.1
PowerEdge R740XD2: before 2.20.1
PowerEdge XR2: before 2.20.1
PowerEdge T440: before 2.20.1
PowerEdge R440: before 2.20.1
PowerEdge R540: before 2.20.1
PowerEdge R940: before 2.20.1
PowerEdge R640: before 2.20.1
PowerEdge R740XD: before 2.20.1
PowerEdge R740: before 2.20.1
PowerEdge XE8545: before 2.13.3
PowerEdge C6525: before 2.13.3
PowerEdge R7525: before 2.13.3
PowerEdge R7515: before 2.13.3
PowerEdge R6525: before 2.13.3
PowerEdge R6515: before 2.13.3
PowerEdge C6615: before 1.1.2
PowerEdge R7625: before 1.6.8
PowerEdge R6625: before 1.6.8
PowerEdge R7615: before 1.6.6
PowerEdge R6615: before 1.6.6
PowerEdge XE9640: before 1.3.6
PowerEdge XE8640: before 1.3.6
PowerEdge XR7620: before 1.6.6
PowerEdge XR8620t: before 1.6.6
PowerEdge XR8610t: before 1.6.6
PowerEdge XR5610: before 1.6.6
PowerEdge XE9680: before 1.3.6
PowerEdge R760xa: before 1.6.6
PowerEdge T560: before 1.6.6
PowerEdge R760xd2: before 1.6.6
PowerEdge R760xs: before 1.6.6
PowerEdge R660xs: before 1.6.6
PowerEdge HS5620: before 1.6.6
PowerEdge HS5610: before 1.6.6
PowerEdge R960: before 1.6.6
PowerEdge R860: before 1.6.6
PowerEdge MX760c: before 1.6.6
PowerEdge C6620: before 1.6.6
PowerEdge R760: before 1.6.6
PowerEdge R660: before 1.6.6
PowerEdge XR4520c: before 1.13.3
PowerEdge XR4510c: before 1.13.3
PowerEdge R350: before 1.8.1
PowerEdge R250: before 1.8.1
PowerEdge T350: before 1.8.1
PowerEdge T150: before 1.8.1
PowerEdge XR12: before 1.12.1
PowerEdge XR11: before 1.12.1
PowerEdge T550: before 1.12.1
PowerEdge R750XS: before 1.12.1
PowerEdge R650XS: before 1.12.1
PowerEdge R450: before 1.12.1
PowerEdge R550: before 1.12.1
PowerEdge MX750c: before 1.12.1
PowerEdge C6520: before 1.12.1
PowerEdge R750XA: before 1.12.1
PowerEdge R750: before 1.12.1
PowerEdge R650: before 1.12.1
CPE2.3Q & A
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the Internet.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.
EUVDB-ID: #VU85525
Risk: Medium
CVSSv4.0: 6.3 [CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/U:Green]
CVE-ID: CVE-2023-45234
CWE-ID:
CWE-119 - Memory corruption
Exploit availability: No
DescriptionThe vulnerability allows a remote attacker to execute arbitrary code on the target system.
The vulnerability exists due to a boundary error when processing DNS Servers option from a DHCPv6 Advertise message. A remote attacker on the local network can trigger memory corruption and execute arbitrary code on the target system.
Successful exploitation of this vulnerability may result in complete compromise of vulnerable system.
MitigationInstall update from vendor's website.
Vulnerable software versionsDell EMC Storage NX3240: before 2.20.1
PowerEdge R730xd: before 2.18.1
PowerEdge R630: before 2.18.1
PowerEdge C4130: before 2.18.1
PowerEdge R930: before 2.13.0
PowerEdge T630: before 2.18.2
PowerEdge R830: before 1.18.1
PowerEdge T130: before 2.19.1
PowerEdge R230: before 2.19.1
PowerEdge T330: before 2.19.1
PowerEdge R330: before 2.19.1
Dell Storage NX430: before 2.19.0
Dell Storage NX3330: before 2.18.1
Dell XC730XD Hyper-converged Appliance: before 2.18.1
Dell XC730 Hyper-converged Appliance: before 2.18.1
Dell XC630 Hyper-converged Appliance: before 2.18.1
Dell XC430 Hyper-converged Appliance: before 2.18.2
Dell XC6320 Hyper-converged Appliance: before 2.18.2
Dell EMC XC Core XC7525: before 2.13.3
Dell EMC XC Core XCXR2: before 2.20.1
Dell EMC XC Core XC940 System: before 2.20.1
Dell EMC XC Core XC740xd2: before 2.20.1
Dell EMC XC Core XC740xd System: before 2.20.1
Dell EMC XC Core XC640 System: before 2.20.1
Dell EMC XC Core 6420 System: before 2.20.1
Dell EMC XC Core XC6520: before 1.12.1
Dell EMC XC Core XC750xa: before 1.12.1
Dell EMC XC Core XC750: before 1.12.1
Dell EMC XC Core XC650: before 1.12.1
Dell EMC XC Core XC450: before 1.12.1
Dell XC Core XC760: before 1.6.6
Dell XC Core XC660: before 1.6.6
Dell Storage NX3230: before 2.18.1
Dell EMC NX440: before 2.15.1
Dell EMC Storage NX3340: before 2.20.1
PowerEdge C6320: before 2.18.2
PowerEdge T430: before 2.18.2
PowerEdge R430: before 2.18.2
PowerEdge R530: before 2.18.2
PowerEdge FC830: before 2.18.1
PowerEdge M830 (for PE VRTX): before 2.18.1
PowerEdge M830: before 2.18.1
PowerEdge FC430: before 2.18.1
PowerEdge FC630: before 2.18.1
PowerEdge M630 (for PE VRTX): before 2.18.1
PowerEdge M630: before 2.18.1
PowerEdge R730: before 2.18.1
PowerEdge R7425: before 1.21.0
PowerEdge R7415: before 1.21.0
PowerEdge R6415: before 1.21.0
PowerEdge R340: before 2.15.1
PowerEdge R240: before 2.15.1
PowerEdge T340: before 2.15.1
PowerEdge T140: before 2.15.1
PowerEdge XE7440: before 2.20.0
PowerEdge XE7420: before 2.20.0
PowerEdge XE2420: before 2.20.0
DSS 8440: before 2.20.0
PowerEdge C4140: before 2.20.1
PowerEdge MX840C: before 2.20.1
PowerEdge MX740C: before 2.20.1
PowerEdge M640 (for PE VRTX): before 2.20.1
PowerEdge M640: before 2.20.1
PowerEdge FC640: before 2.20.1
PowerEdge C6420: before 2.20.1
PowerEdge T640: before 2.20.1
PowerEdge R940XA: before 2.20.1
PowerEdge R840: before 2.20.1
PowerEdge R740XD2: before 2.20.1
PowerEdge XR2: before 2.20.1
PowerEdge T440: before 2.20.1
PowerEdge R440: before 2.20.1
PowerEdge R540: before 2.20.1
PowerEdge R940: before 2.20.1
PowerEdge R640: before 2.20.1
PowerEdge R740XD: before 2.20.1
PowerEdge R740: before 2.20.1
PowerEdge XE8545: before 2.13.3
PowerEdge C6525: before 2.13.3
PowerEdge R7525: before 2.13.3
PowerEdge R7515: before 2.13.3
PowerEdge R6525: before 2.13.3
PowerEdge R6515: before 2.13.3
PowerEdge C6615: before 1.1.2
PowerEdge R7625: before 1.6.8
PowerEdge R6625: before 1.6.8
PowerEdge R7615: before 1.6.6
PowerEdge R6615: before 1.6.6
PowerEdge XE9640: before 1.3.6
PowerEdge XE8640: before 1.3.6
PowerEdge XR7620: before 1.6.6
PowerEdge XR8620t: before 1.6.6
PowerEdge XR8610t: before 1.6.6
PowerEdge XR5610: before 1.6.6
PowerEdge XE9680: before 1.3.6
PowerEdge R760xa: before 1.6.6
PowerEdge T560: before 1.6.6
PowerEdge R760xd2: before 1.6.6
PowerEdge R760xs: before 1.6.6
PowerEdge R660xs: before 1.6.6
PowerEdge HS5620: before 1.6.6
PowerEdge HS5610: before 1.6.6
PowerEdge R960: before 1.6.6
PowerEdge R860: before 1.6.6
PowerEdge MX760c: before 1.6.6
PowerEdge C6620: before 1.6.6
PowerEdge R760: before 1.6.6
PowerEdge R660: before 1.6.6
PowerEdge XR4520c: before 1.13.3
PowerEdge XR4510c: before 1.13.3
PowerEdge R350: before 1.8.1
PowerEdge R250: before 1.8.1
PowerEdge T350: before 1.8.1
PowerEdge T150: before 1.8.1
PowerEdge XR12: before 1.12.1
PowerEdge XR11: before 1.12.1
PowerEdge T550: before 1.12.1
PowerEdge R750XS: before 1.12.1
PowerEdge R650XS: before 1.12.1
PowerEdge R450: before 1.12.1
PowerEdge R550: before 1.12.1
PowerEdge MX750c: before 1.12.1
PowerEdge C6520: before 1.12.1
PowerEdge R750XA: before 1.12.1
PowerEdge R750: before 1.12.1
PowerEdge R650: before 1.12.1
CPE2.3Q & A
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the local network (LAN).
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.
EUVDB-ID: #VU85526
Risk: Medium
CVSSv4.0: 6.3 [CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/U:Green]
CVE-ID: CVE-2023-45235
CWE-ID:
CWE-119 - Memory corruption
Exploit availability: No
DescriptionThe vulnerability allows a remote attacker to execute arbitrary code on the target system.
The vulnerability exists due to a boundary error when handling Server ID option from a DHCPv6 proxy Advertise message. A remote attacker on the local network can trigger memory corruption and execute arbitrary code on the target system.
Successful exploitation of this vulnerability may result in complete compromise of vulnerable system.
MitigationInstall update from vendor's website.
Vulnerable software versionsDell EMC Storage NX3240: before 2.20.1
PowerEdge R730xd: before 2.18.1
PowerEdge R630: before 2.18.1
PowerEdge C4130: before 2.18.1
PowerEdge R930: before 2.13.0
PowerEdge T630: before 2.18.2
PowerEdge R830: before 1.18.1
PowerEdge T130: before 2.19.1
PowerEdge R230: before 2.19.1
PowerEdge T330: before 2.19.1
PowerEdge R330: before 2.19.1
Dell Storage NX430: before 2.19.0
Dell Storage NX3330: before 2.18.1
Dell XC730XD Hyper-converged Appliance: before 2.18.1
Dell XC730 Hyper-converged Appliance: before 2.18.1
Dell XC630 Hyper-converged Appliance: before 2.18.1
Dell XC430 Hyper-converged Appliance: before 2.18.2
Dell XC6320 Hyper-converged Appliance: before 2.18.2
Dell EMC XC Core XC7525: before 2.13.3
Dell EMC XC Core XCXR2: before 2.20.1
Dell EMC XC Core XC940 System: before 2.20.1
Dell EMC XC Core XC740xd2: before 2.20.1
Dell EMC XC Core XC740xd System: before 2.20.1
Dell EMC XC Core XC640 System: before 2.20.1
Dell EMC XC Core 6420 System: before 2.20.1
Dell EMC XC Core XC6520: before 1.12.1
Dell EMC XC Core XC750xa: before 1.12.1
Dell EMC XC Core XC750: before 1.12.1
Dell EMC XC Core XC650: before 1.12.1
Dell EMC XC Core XC450: before 1.12.1
Dell XC Core XC760: before 1.6.6
Dell XC Core XC660: before 1.6.6
Dell Storage NX3230: before 2.18.1
Dell EMC NX440: before 2.15.1
Dell EMC Storage NX3340: before 2.20.1
PowerEdge C6320: before 2.18.2
PowerEdge T430: before 2.18.2
PowerEdge R430: before 2.18.2
PowerEdge R530: before 2.18.2
PowerEdge FC830: before 2.18.1
PowerEdge M830 (for PE VRTX): before 2.18.1
PowerEdge M830: before 2.18.1
PowerEdge FC430: before 2.18.1
PowerEdge FC630: before 2.18.1
PowerEdge M630 (for PE VRTX): before 2.18.1
PowerEdge M630: before 2.18.1
PowerEdge R730: before 2.18.1
PowerEdge R7425: before 1.21.0
PowerEdge R7415: before 1.21.0
PowerEdge R6415: before 1.21.0
PowerEdge R340: before 2.15.1
PowerEdge R240: before 2.15.1
PowerEdge T340: before 2.15.1
PowerEdge T140: before 2.15.1
PowerEdge XE7440: before 2.20.0
PowerEdge XE7420: before 2.20.0
PowerEdge XE2420: before 2.20.0
DSS 8440: before 2.20.0
PowerEdge C4140: before 2.20.1
PowerEdge MX840C: before 2.20.1
PowerEdge MX740C: before 2.20.1
PowerEdge M640 (for PE VRTX): before 2.20.1
PowerEdge M640: before 2.20.1
PowerEdge FC640: before 2.20.1
PowerEdge C6420: before 2.20.1
PowerEdge T640: before 2.20.1
PowerEdge R940XA: before 2.20.1
PowerEdge R840: before 2.20.1
PowerEdge R740XD2: before 2.20.1
PowerEdge XR2: before 2.20.1
PowerEdge T440: before 2.20.1
PowerEdge R440: before 2.20.1
PowerEdge R540: before 2.20.1
PowerEdge R940: before 2.20.1
PowerEdge R640: before 2.20.1
PowerEdge R740XD: before 2.20.1
PowerEdge R740: before 2.20.1
PowerEdge XE8545: before 2.13.3
PowerEdge C6525: before 2.13.3
PowerEdge R7525: before 2.13.3
PowerEdge R7515: before 2.13.3
PowerEdge R6525: before 2.13.3
PowerEdge R6515: before 2.13.3
PowerEdge C6615: before 1.1.2
PowerEdge R7625: before 1.6.8
PowerEdge R6625: before 1.6.8
PowerEdge R7615: before 1.6.6
PowerEdge R6615: before 1.6.6
PowerEdge XE9640: before 1.3.6
PowerEdge XE8640: before 1.3.6
PowerEdge XR7620: before 1.6.6
PowerEdge XR8620t: before 1.6.6
PowerEdge XR8610t: before 1.6.6
PowerEdge XR5610: before 1.6.6
PowerEdge XE9680: before 1.3.6
PowerEdge R760xa: before 1.6.6
PowerEdge T560: before 1.6.6
PowerEdge R760xd2: before 1.6.6
PowerEdge R760xs: before 1.6.6
PowerEdge R660xs: before 1.6.6
PowerEdge HS5620: before 1.6.6
PowerEdge HS5610: before 1.6.6
PowerEdge R960: before 1.6.6
PowerEdge R860: before 1.6.6
PowerEdge MX760c: before 1.6.6
PowerEdge C6620: before 1.6.6
PowerEdge R760: before 1.6.6
PowerEdge R660: before 1.6.6
PowerEdge XR4520c: before 1.13.3
PowerEdge XR4510c: before 1.13.3
PowerEdge R350: before 1.8.1
PowerEdge R250: before 1.8.1
PowerEdge T350: before 1.8.1
PowerEdge T150: before 1.8.1
PowerEdge XR12: before 1.12.1
PowerEdge XR11: before 1.12.1
PowerEdge T550: before 1.12.1
PowerEdge R750XS: before 1.12.1
PowerEdge R650XS: before 1.12.1
PowerEdge R450: before 1.12.1
PowerEdge R550: before 1.12.1
PowerEdge MX750c: before 1.12.1
PowerEdge C6520: before 1.12.1
PowerEdge R750XA: before 1.12.1
PowerEdge R750: before 1.12.1
PowerEdge R650: before 1.12.1
CPE2.3Q & A
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the local network (LAN).
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.
EUVDB-ID: #VU85527
Risk: Low
CVSSv4.0: 1.3 [CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:U/U:Clear]
CVE-ID: CVE-2023-45236
CWE-ID:
CWE-338 - Use of Cryptographically Weak Pseudo-Random Number Generator (PRNG)
Exploit availability: No
DescriptionThe vulnerability allows a remote attacker to gain access to potentially sensitive information.
The vulnerability exists due to a predictable TCP Initial Sequence Number. A remote attacker on the local network can gain unauthorized access to sensitive information on the system.
MitigationInstall update from vendor's website.
Vulnerable software versionsDell EMC Storage NX3240: before 2.20.1
PowerEdge R730xd: before 2.18.1
PowerEdge R630: before 2.18.1
PowerEdge C4130: before 2.18.1
PowerEdge R930: before 2.13.0
PowerEdge T630: before 2.18.2
PowerEdge R830: before 1.18.1
PowerEdge T130: before 2.19.1
PowerEdge R230: before 2.19.1
PowerEdge T330: before 2.19.1
PowerEdge R330: before 2.19.1
Dell Storage NX430: before 2.19.0
Dell Storage NX3330: before 2.18.1
Dell XC730XD Hyper-converged Appliance: before 2.18.1
Dell XC730 Hyper-converged Appliance: before 2.18.1
Dell XC630 Hyper-converged Appliance: before 2.18.1
Dell XC430 Hyper-converged Appliance: before 2.18.2
Dell XC6320 Hyper-converged Appliance: before 2.18.2
Dell EMC XC Core XC7525: before 2.13.3
Dell EMC XC Core XCXR2: before 2.20.1
Dell EMC XC Core XC940 System: before 2.20.1
Dell EMC XC Core XC740xd2: before 2.20.1
Dell EMC XC Core XC740xd System: before 2.20.1
Dell EMC XC Core XC640 System: before 2.20.1
Dell EMC XC Core 6420 System: before 2.20.1
Dell EMC XC Core XC6520: before 1.12.1
Dell EMC XC Core XC750xa: before 1.12.1
Dell EMC XC Core XC750: before 1.12.1
Dell EMC XC Core XC650: before 1.12.1
Dell EMC XC Core XC450: before 1.12.1
Dell XC Core XC760: before 1.6.6
Dell XC Core XC660: before 1.6.6
Dell Storage NX3230: before 2.18.1
Dell EMC NX440: before 2.15.1
Dell EMC Storage NX3340: before 2.20.1
PowerEdge C6320: before 2.18.2
PowerEdge T430: before 2.18.2
PowerEdge R430: before 2.18.2
PowerEdge R530: before 2.18.2
PowerEdge FC830: before 2.18.1
PowerEdge M830 (for PE VRTX): before 2.18.1
PowerEdge M830: before 2.18.1
PowerEdge FC430: before 2.18.1
PowerEdge FC630: before 2.18.1
PowerEdge M630 (for PE VRTX): before 2.18.1
PowerEdge M630: before 2.18.1
PowerEdge R730: before 2.18.1
PowerEdge R7425: before 1.21.0
PowerEdge R7415: before 1.21.0
PowerEdge R6415: before 1.21.0
PowerEdge R340: before 2.15.1
PowerEdge R240: before 2.15.1
PowerEdge T340: before 2.15.1
PowerEdge T140: before 2.15.1
PowerEdge XE7440: before 2.20.0
PowerEdge XE7420: before 2.20.0
PowerEdge XE2420: before 2.20.0
DSS 8440: before 2.20.0
PowerEdge C4140: before 2.20.1
PowerEdge MX840C: before 2.20.1
PowerEdge MX740C: before 2.20.1
PowerEdge M640 (for PE VRTX): before 2.20.1
PowerEdge M640: before 2.20.1
PowerEdge FC640: before 2.20.1
PowerEdge C6420: before 2.20.1
PowerEdge T640: before 2.20.1
PowerEdge R940XA: before 2.20.1
PowerEdge R840: before 2.20.1
PowerEdge R740XD2: before 2.20.1
PowerEdge XR2: before 2.20.1
PowerEdge T440: before 2.20.1
PowerEdge R440: before 2.20.1
PowerEdge R540: before 2.20.1
PowerEdge R940: before 2.20.1
PowerEdge R640: before 2.20.1
PowerEdge R740XD: before 2.20.1
PowerEdge R740: before 2.20.1
PowerEdge XE8545: before 2.13.3
PowerEdge C6525: before 2.13.3
PowerEdge R7525: before 2.13.3
PowerEdge R7515: before 2.13.3
PowerEdge R6525: before 2.13.3
PowerEdge R6515: before 2.13.3
PowerEdge C6615: before 1.1.2
PowerEdge R7625: before 1.6.8
PowerEdge R6625: before 1.6.8
PowerEdge R7615: before 1.6.6
PowerEdge R6615: before 1.6.6
PowerEdge XE9640: before 1.3.6
PowerEdge XE8640: before 1.3.6
PowerEdge XR7620: before 1.6.6
PowerEdge XR8620t: before 1.6.6
PowerEdge XR8610t: before 1.6.6
PowerEdge XR5610: before 1.6.6
PowerEdge XE9680: before 1.3.6
PowerEdge R760xa: before 1.6.6
PowerEdge T560: before 1.6.6
PowerEdge R760xd2: before 1.6.6
PowerEdge R760xs: before 1.6.6
PowerEdge R660xs: before 1.6.6
PowerEdge HS5620: before 1.6.6
PowerEdge HS5610: before 1.6.6
PowerEdge R960: before 1.6.6
PowerEdge R860: before 1.6.6
PowerEdge MX760c: before 1.6.6
PowerEdge C6620: before 1.6.6
PowerEdge R760: before 1.6.6
PowerEdge R660: before 1.6.6
PowerEdge XR4520c: before 1.13.3
PowerEdge XR4510c: before 1.13.3
PowerEdge R350: before 1.8.1
PowerEdge R250: before 1.8.1
PowerEdge T350: before 1.8.1
PowerEdge T150: before 1.8.1
PowerEdge XR12: before 1.12.1
PowerEdge XR11: before 1.12.1
PowerEdge T550: before 1.12.1
PowerEdge R750XS: before 1.12.1
PowerEdge R650XS: before 1.12.1
PowerEdge R450: before 1.12.1
PowerEdge R550: before 1.12.1
PowerEdge MX750c: before 1.12.1
PowerEdge C6520: before 1.12.1
PowerEdge R750XA: before 1.12.1
PowerEdge R750: before 1.12.1
PowerEdge R650: before 1.12.1
CPE2.3Q & A
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the local network (LAN).
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.
EUVDB-ID: #VU85528
Risk: Medium
CVSSv4.0: 2.7 [CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:U/U:Green]
CVE-ID: CVE-2023-45237
CWE-ID:
CWE-338 - Use of Cryptographically Weak Pseudo-Random Number Generator (PRNG)
Exploit availability: No
DescriptionThe vulnerability allows a remote attacker to gain access to potentially sensitive information.
The vulnerability exists due to a predictable TCP Initial Sequence Number. A remote attacker can gain unauthorized access to sensitive information on the system.
MitigationInstall update from vendor's website.
Vulnerable software versionsDell EMC Storage NX3240: before 2.20.1
PowerEdge R730xd: before 2.18.1
PowerEdge R630: before 2.18.1
PowerEdge C4130: before 2.18.1
PowerEdge R930: before 2.13.0
PowerEdge T630: before 2.18.2
PowerEdge R830: before 1.18.1
PowerEdge T130: before 2.19.1
PowerEdge R230: before 2.19.1
PowerEdge T330: before 2.19.1
PowerEdge R330: before 2.19.1
Dell Storage NX430: before 2.19.0
Dell Storage NX3330: before 2.18.1
Dell XC730XD Hyper-converged Appliance: before 2.18.1
Dell XC730 Hyper-converged Appliance: before 2.18.1
Dell XC630 Hyper-converged Appliance: before 2.18.1
Dell XC430 Hyper-converged Appliance: before 2.18.2
Dell XC6320 Hyper-converged Appliance: before 2.18.2
Dell EMC XC Core XC7525: before 2.13.3
Dell EMC XC Core XCXR2: before 2.20.1
Dell EMC XC Core XC940 System: before 2.20.1
Dell EMC XC Core XC740xd2: before 2.20.1
Dell EMC XC Core XC740xd System: before 2.20.1
Dell EMC XC Core XC640 System: before 2.20.1
Dell EMC XC Core 6420 System: before 2.20.1
Dell EMC XC Core XC6520: before 1.12.1
Dell EMC XC Core XC750xa: before 1.12.1
Dell EMC XC Core XC750: before 1.12.1
Dell EMC XC Core XC650: before 1.12.1
Dell EMC XC Core XC450: before 1.12.1
Dell XC Core XC760: before 1.6.6
Dell XC Core XC660: before 1.6.6
Dell Storage NX3230: before 2.18.1
Dell EMC NX440: before 2.15.1
Dell EMC Storage NX3340: before 2.20.1
PowerEdge C6320: before 2.18.2
PowerEdge T430: before 2.18.2
PowerEdge R430: before 2.18.2
PowerEdge R530: before 2.18.2
PowerEdge FC830: before 2.18.1
PowerEdge M830 (for PE VRTX): before 2.18.1
PowerEdge M830: before 2.18.1
PowerEdge FC430: before 2.18.1
PowerEdge FC630: before 2.18.1
PowerEdge M630 (for PE VRTX): before 2.18.1
PowerEdge M630: before 2.18.1
PowerEdge R730: before 2.18.1
PowerEdge R7425: before 1.21.0
PowerEdge R7415: before 1.21.0
PowerEdge R6415: before 1.21.0
PowerEdge R340: before 2.15.1
PowerEdge R240: before 2.15.1
PowerEdge T340: before 2.15.1
PowerEdge T140: before 2.15.1
PowerEdge XE7440: before 2.20.0
PowerEdge XE7420: before 2.20.0
PowerEdge XE2420: before 2.20.0
DSS 8440: before 2.20.0
PowerEdge C4140: before 2.20.1
PowerEdge MX840C: before 2.20.1
PowerEdge MX740C: before 2.20.1
PowerEdge M640 (for PE VRTX): before 2.20.1
PowerEdge M640: before 2.20.1
PowerEdge FC640: before 2.20.1
PowerEdge C6420: before 2.20.1
PowerEdge T640: before 2.20.1
PowerEdge R940XA: before 2.20.1
PowerEdge R840: before 2.20.1
PowerEdge R740XD2: before 2.20.1
PowerEdge XR2: before 2.20.1
PowerEdge T440: before 2.20.1
PowerEdge R440: before 2.20.1
PowerEdge R540: before 2.20.1
PowerEdge R940: before 2.20.1
PowerEdge R640: before 2.20.1
PowerEdge R740XD: before 2.20.1
PowerEdge R740: before 2.20.1
PowerEdge XE8545: before 2.13.3
PowerEdge C6525: before 2.13.3
PowerEdge R7525: before 2.13.3
PowerEdge R7515: before 2.13.3
PowerEdge R6525: before 2.13.3
PowerEdge R6515: before 2.13.3
PowerEdge C6615: before 1.1.2
PowerEdge R7625: before 1.6.8
PowerEdge R6625: before 1.6.8
PowerEdge R7615: before 1.6.6
PowerEdge R6615: before 1.6.6
PowerEdge XE9640: before 1.3.6
PowerEdge XE8640: before 1.3.6
PowerEdge XR7620: before 1.6.6
PowerEdge XR8620t: before 1.6.6
PowerEdge XR8610t: before 1.6.6
PowerEdge XR5610: before 1.6.6
PowerEdge XE9680: before 1.3.6
PowerEdge R760xa: before 1.6.6
PowerEdge T560: before 1.6.6
PowerEdge R760xd2: before 1.6.6
PowerEdge R760xs: before 1.6.6
PowerEdge R660xs: before 1.6.6
PowerEdge HS5620: before 1.6.6
PowerEdge HS5610: before 1.6.6
PowerEdge R960: before 1.6.6
PowerEdge R860: before 1.6.6
PowerEdge MX760c: before 1.6.6
PowerEdge C6620: before 1.6.6
PowerEdge R760: before 1.6.6
PowerEdge R660: before 1.6.6
PowerEdge XR4520c: before 1.13.3
PowerEdge XR4510c: before 1.13.3
PowerEdge R350: before 1.8.1
PowerEdge R250: before 1.8.1
PowerEdge T350: before 1.8.1
PowerEdge T150: before 1.8.1
PowerEdge XR12: before 1.12.1
PowerEdge XR11: before 1.12.1
PowerEdge T550: before 1.12.1
PowerEdge R750XS: before 1.12.1
PowerEdge R650XS: before 1.12.1
PowerEdge R450: before 1.12.1
PowerEdge R550: before 1.12.1
PowerEdge MX750c: before 1.12.1
PowerEdge C6520: before 1.12.1
PowerEdge R750XA: before 1.12.1
PowerEdge R750: before 1.12.1
PowerEdge R650: before 1.12.1
CPE2.3Q & A
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the Internet.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.