Known vulnerabilities in SINAMICS S120
Vendor:
Siemens
Software:
SINAMICS S120
Software CPE:
cpe:2.3:h:siemens:sinamics_s120:*:*:*:*:*:*:*:*
Website:
https://www.siemens.com/
Total vulnerabilities:
5
Public exploits:
0
Known exploited (KEV):
0
Highest CVSSv4 Score:
8.8
Breakdown by Severity Chart
Vulnerabilities (5)
| Vulnerability | CWE-ID | CSH Severity | Public Exploit | KEV | First fixed release | Published | Bulletins |
|---|---|---|---|---|---|---|---|
| #VU84390 - Memory corruption CVE-2022-47375 |
CWE-119 | Medium | 5.2 SP3 HF15 | 13.12.2023 |
SB2023121335 |
||
| #VU84387 - Uncontrolled Recursion CVE-2022-47374 |
CWE-674 | Medium | 5.2 SP3 HF15 | 13.12.2023 |
SB2023121335 |
||
| #VU21936 - Resource exhaustion CVE-2019-10936 |
CWE-400 | Medium | - | 18.10.2019 |
SB2019101013 |
||
| #VU21932 - Improper input validation CVE-2019-10923 |
CWE-20 | Medium | 4.7 HF34 | 18.10.2019 |
SB2019101012 |
||
| #VU9545 - Improper input validation CVE-2017-12741 |
CWE-20 | Low | - | 05.12.2017 |
SB2017120603 |