Risk | Low |
Patch available | YES |
Number of vulnerabilities | 1 |
CVE-ID | CVE-2019-13924 |
CWE-ID | CWE-693 |
Exploitation vector | Network |
Public exploit | N/A |
Vulnerable software Subscribe |
SCALANCE X-200 Hardware solutions / Routers & switches, VoIP, GSM, etc SCALANCE X-200 IRT Hardware solutions / Routers & switches, VoIP, GSM, etc SCALANCE X-300 Hardware solutions / Routers & switches, VoIP, GSM, etc |
Vendor | Siemens |
Security Bulletin
This security bulletin contains one low risk vulnerability.
EUVDB-ID: #VU25260
Risk: Low
CVSSv3.1:
CVE-ID: CVE-2019-13924
CWE-ID:
CWE-693 - Protection Mechanism Failure
Exploit availability: No
DescriptionThe vulnerability allows a remote attacker to bypass implemented security restrictions.
The vulnerability exists due to the affected device does not send the X-Frame-Option header in the administrative web interface. A remote attacker can perform a click-jacking attack, bypass implemented security restrictions and elevate privileges on the system.
MitigationInstall updates from vendor's website.
Vulnerable software versionsSCALANCE X-200: before 5.2.4
SCALANCE X-200 IRT: All versions
SCALANCE X-300: before 4.1.3
CPE2.3 External linkshttp://cert-portal.siemens.com/productcert/pdf/ssa-951513.pdf
Q & A
Can this vulnerability be exploited remotely?
How the attacker can exploit this vulnerability?
Is there known malware, which exploits this vulnerability?