Vulnerability identifier: #VU64426
Vulnerability risk: Medium
CVSSv4.0: 6.3 [CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/U:Green]
CVE-ID:
CWE-ID:
CWE-306
Exploitation vector: Network
Exploit availability: No
Vulnerable software:
SINEMA Remote Connect Server
Server applications /
SCADA systems
Vendor: Siemens
Description
The vulnerability allows a remote attacker to bypass authentication process.
The vulnerability exists due to missing authentication verification for a resource used to change the roles and permissions of a user. A remote user can change the permissions of any user and gain the privileges of an administrative user
Mitigation
Install updates from vendor's website.
Vulnerable software versions
SINEMA Remote Connect Server: before 3.1
External links
https://cert-portal.siemens.com/productcert/txt/ssa-484086.txt
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote authenticated user via the Internet.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.