#VU67369 Out-of-bounds read in Parasolid and Simcenter Femap - CVE-2022-39137


| Updated: 2022-09-18

Vulnerability identifier: #VU67369

Vulnerability risk: Low

CVSSv4.0: 1.2 [CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:U/U:Clear]

CVE-ID: CVE-2022-39137

CWE-ID: CWE-125

Exploitation vector: Network

Exploit availability: No

Vulnerable software:
Parasolid
Client/Desktop applications / Other client software
Simcenter Femap
Server applications / SCADA systems

Vendor: Siemens

Description

The vulnerability allows a remote attacker to gain access to potentially sensitive information.

The vulnerability exists due to a boundary condition when parsing X_T files. A remote attacker can create a specially crafted file, trick the victim into opening it, trigger out-of-bounds read error and read contents of memory on the system.

Mitigation
Install updates from vendor's website.

Vulnerable software versions

Parasolid: before 33.1.262

Simcenter Femap: before 2022.1.3


External links
https://cert-portal.siemens.com/productcert/txt/ssa-518824.txt
https://www.zerodayinitiative.com/advisories/ZDI-22-1230/


Q & A

Can this vulnerability be exploited remotely?

Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the Internet.

Is there known malware, which exploits this vulnerability?

No. We are not aware of malware exploiting this vulnerability.