Vulnerability identifier: #VU80759
Vulnerability risk: Low
CVSSv4.0: 0.4 [CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:A/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N/E:U/U:Clear]
CVE-ID:
CWE-ID:
CWE-613
Exploitation vector: Local
Exploit availability: No
Vulnerable software:
QMS Automotive
Server applications /
SCADA systems
Vendor: Siemens
Description
The vulnerability allows a local user to gain access to sensitive information.
The vulnerability exists due to insufficient session expiration issue in the QMS.Mobile module. A local user can perform session hijacking attacks.
Mitigation
Install updates from vendor's website.
Vulnerable software versions
QMS Automotive: before 12.39
External links
https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf