#VU50135 Out-of-bounds write in IGSS SCADA


Vulnerability identifier: #VU50135

Vulnerability risk: High

CVSSv4.0: 6.1 [CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/U:Amber]

CVE-ID: N/A

CWE-ID: CWE-787

Exploitation vector: Network

Exploit availability: No

Vulnerable software:
IGSS SCADA
Server applications / SCADA systems

Vendor: Schneider Electric

Description

The vulnerability allows a remote attacker to compromise vulnerable system.

The vulnerability exists due to a boundary error when processing CGF files. A remote attacker can create a specially crafted CGF file, trick the victim into opening it using the affected software, trigger out-of-bounds write and execute arbitrary code on the target system.

Mitigation
Cybersecurity Help is currently unaware of any official solution to address this vulnerability.

Vulnerable software versions

IGSS SCADA: 2 - 14.0.0.20248


External links
https://www.zerodayinitiative.com/advisories/ZDI-21-095/


Q & A

Can this vulnerability be exploited remotely?

Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the Internet.

Is there known malware, which exploits this vulnerability?

No. We are not aware of malware exploiting this vulnerability.


Latest bulletins with this vulnerability